PTF MH01197 requires corrective service Mandatory fix for HMC Version 7 Release 3.5.0 This package includes fixes for HMC Version 7 Release 3.5.0 (SP0) only. You can reference this package by APAR MB03131. Before you install this fix, PTF MH01197, you must first install PTF MH01195, the mandatory efix for HMC V7.3.5.0. Package information Package name Size Checksum APAR# PTF# MH01197.iso 124393472 04566 MB03131 MH01197 Splash panel information (lshmc -v output) NOTE: HMC V7 R3.4.0 (and later) can install corrective service directly from ISO files. The ZIP file format is no longer provided. ==> lshmc -V "version= Version: 7 Release: 3.5.0 Service Pack: 0 HMC Build level 20091112.1 MH01195: Required fix for HMC V7R3.5.0 (10-16-2009) MH01197: Fix for HMC V7R3.5.0 (11-12-2009) ","base_version=V7R3.5.0 " List of fixes This package includes the following fixes: * Fixes communication issues between IBM Director and HMC. * Fixes a problem with the HMC service data collection commands. The data collection fails to collect the javacore and heapdump files for the main Java process of the console, as intended. In addition, a subsequent serviceable event, with reference code E332FFFF, is opened on the console and called home. (This serviceable event collects the files that were left uncollected by the command.) * Fixes a "launch in context" problem where IBM Director uses the wrong port to launch a web browser connection to the HMC. * Fixes a problem with cross HMC partition migrations when the client partition uses non zero virtual switch id for vlans, An activate migration would fail; inactive migration would complete but have a profile with wrong vlan setting. * Fixes a problem with handling of system dumps when /dump directory is full. * Fixes a problem with concurrent node maintenance on model MMA when the node contains the primary FSP. * Fixes a problem where HMC inventory would include stale partition informa-tion in the results. * Fixed a problem on POWER 595 where the C10 I/O slot would not be displayed during the add or Remove FRU task. * When multiple updlic commands are run simultaneously the following error message may occur: "An unknown error occurred while trying to perform this command. Retry the command. If the error persists, contact your software support representative." * In HMC V7.3.5.0, when a partition does not have a last activated profile, lssyscfg -r lpar -F curr_profile outputs "none". Previously, lssyscfg -r lpar -F curr_profile output "" (an empty string). This defect causes lssyscfg -r lpar -F curr_profile to revert back to its previous behavior for partitions that do not have a last activated profile, and output "" again. * The lpar_netboot command creates log files in /tmp such that later execution will cause a log file collision resulting in a failure due to permission error. The fix allows lpar_netboot to execute without encountering the permission error.