IBM Storwize V7000 Unified ++++++++++++++++++++++++++ --------------------------------------------------------------------------------- CONTENTS 1. Introduction 2. Prerequisites 3. Code Levels 4. Problems Resolved and New Features 4.1 Features added and withdrawn in IBM Storwize V7000 Unified File Module 1.5.2.6. 4.2 APARs resolved in IBM Storwize V7000 Unified File Module 1.5.2.6 4.3 New features in Storwize V7000 7.4.0.10-103.27.1605260000 4.4 APARs resolved in Storwize V7000 7.4.0.10-103.27.1605260000 5. Further Documentation 6. Known Issues and Restrictions in this Level 7. Maximum Configurations 8. Supported Hardware 9. Pre-1.5.2.6 Release Information 9.1 Storwize V7000 Unified version 1.5.2.5 9.2 Storwize V7000 Unified version 1.5.2.4 9.3 Storwize V7000 Unified version 1.5.2.3 9.4 Storwize V7000 Unified version 1.5.2.2 9.5 Storwize V7000 Unified version 1.5.2.1 9.6 Storwize V7000 Unified version 1.5.2.0 9.7 Storwize V7000 Unified version 1.5.1.3 9.8 Storwize V7000 Unified version 1.5.1.2 9.9 Storwize V7000 Unified version 1.5.1.1 9.10 Storwize V7000 Unified version 1.5.1.0 9.11 APARs resolved in previous Storwize V7000 7.4.x releases ---------------------------------------------------------------------------------- 1. Introduction This document contains important information about version 1.5.2.6 of the IBM Storwize V7000 Unified software. ---------------------------------------------------------------------------------- 2. Prerequisites Software Upgrade Test Utility: The software upgrade test utility "upgradetest" must be run within two hours of starting the upgrade. The upgrade test utility can be run as many times as required, but there must be a successful run of the upgrade test utility within two hours of starting the upgrade. Refer to the following URL for further information: http://www.ibm.com/support/docview.wss?uid=ssg1S4000986 Concurrent Upgrades: The concurrent upgrade (upgrade with I/O running) restrictions are documented at the following URL: http://www.ibm.com/support/docview.wss?uid=ssg1S1004680#_Restrictions_Upgrade If you are performing a concurrent code upgrade, first ensure that all host paths are available and operating correctly. System Performance: Performance of the IBM Storwize V7000 Unified will be degraded during the software upgrade process. IBM recommends you perform the upgrade at a time of lower overall I/O activity and when significant spikes in the system workload are not expected. Event Checking: Check there are no unfixed events in the event log. Use normal service procedures to resolve any events before proceeding. Asynchronous Replication Systems: If the system is part of an asynchronous relationship (either source or target), stop the replication to avoid asynchronous replication failures during upgrade. Full upgrade compatibility matrix: Please see the following web page for the full upgrade compatibility matrix. http://www.ibm.com/support/docview.wss?uid=ssg1S1003918 ------------------------------------------------------------------------------------- 3. Code Levels Storwize V7000 Unified Software: Storwize V7000 Unified Product Version 1.5.2.6 (1.5.2.6-12) This includes Storwize V7000 (2076) Product Version: 7.4.0.10 (103.27.1605260000) ------------------------------------------------------------------------------------- 4. Problems Resolved and New Features 4.1 Features added and withdrawn in IBM Storwize V7000 Unified File Module 1.5.2.6. None 4.2 Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.6: Security Fixes For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER) http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified Critical Fixes HU01511 CIFS shares having option 'hide unreadable' set to 'yes' may get disconnected if CTDB ping times out under heavy system load. HU01532 Access to the system may be lost under certain conditions while CTDB is revoking READONLY delegations. High Importance Fixes HU01518 Repeated INFO messages indicating a restart of vsftpd service, such as "A start service was detected with vsftpd" and "A stopped or failed service was detected with vsftpd". HU01527 Migration policy created for fileset with CLI cannot be managed from GUI. HU01529 After upgrade to 1.5.2.3-14, username and groupname is seen as 'nobody' causing NFS shares to not mount. HU01530 After upgrade to 1.5.2.5-11, some CIFS share users may get 'Permission denied' and 'No space on disk' error messages while accessing files, directories having long ACLs. HU01533 Multiple execution of 'lsexport' on systems configured with large number of NFS shares, floods system log with message 'EFSSG0745C Database temporarily not available. Cause: Too many open connections' HU01514 NFSv4 enters defunct state while shutting down. HU01493 GPFS assert causes filesystem to unmount logging return code 19 in system logs. Suggested Fixes HU01491 Update man page for 'chwache' CLI under option '--disablewcache' with restrictions for conversion of independent and single writer wcache filesets to normal filesets. 4.3 New features in Storwize V7000 7.4.0.10: None 4.4 Issues resolved in Storwize V7000 7.4.0.10: High Importance HU00726 Single node assert due to stuck IO following offline mdisk group condition. IT14917 Node asserts due to a timing window in the cache component. Suggested HU01024 A single node assert may occur when the SAS firmware's ECC checking detects a single bit error. The assert clears the error condition in the SAS chip. HU01097 For a small number of node asserts the SAS register values are retaining incorrect values rendering the debug information invalid. ----------------------------------------------------------------------------------- 5. Further Documentation The latest version of all IBM Storwize V7000 Unified documentation is available in the IBM Storwize V7000 Unified 1.5.2 Knowledge Center: http://www.ibm.com/support/knowledgecenter/ST5Q4U/landing/v7000_unified_welcome.htm?lang=en Selected documents are available for download in PDF format from the support website: http://www.ibm.com/storage/support/storwize/V7000/unified Please refer to below link for a consolidated list of highly recommended reference material on IBM Storwize V7000 Unified http://www-01.ibm.com/support/docview.wss?uid=ssg1S1004460 ----------------------------------------------------------------------------------- 6. Known Issues and Restrictions in this Level * The software upgrade package for Storwize V7000 Unified V1.5.2.6 is larger than 2GB in size. So when you attempt to upload the Storwize V7000 Unified V1.5.2.6 software upgrade package to the Storwize V7000 Unified system using Microsoft Internet Explorer 8 or lower you may find that the upload does not complete. This is a limitation of the browser. For more information, please refer to: http://support.microsoft.com/kb/298618 Please use Microsoft Internet Explorer 10 or higher or some other browser like Mozilla Firefox or Google Chrome when uploading the Storwize V7000 Unified V1.5.2.6 upgrade package to the Storwize V7000 Unified system. Refer to the below technote for more information on this issue: http://www-01.ibm.com/support/docview.wss?uid=ssg1S1004700 * In IBM Storwize V7000 Unified, Windows 8 with offline folders is not currently supported. * Browsers with below listed levels are certified for using the IBM Storwize V7000 Unified Management GUI. Mozilla Firefox 46 Mozilla Firefox Extended Support Release (ESR) 45 Important: All Firefox users should upgrade to these updated packages, which contain Firefox version 45.x ESR. After installing the update, Firefox must be restarted for the changes to take effect. For Red Hat Linux users, make sure all previously released errata relevant to your system have been applied before applying this update. This update is available at the Red Hat Network: https://rhn.redhat.com/errata/RHSA-2016-0695.html Details on how to use the Red Hat Network to apply this update are available at https://access.redhat.com/knowledge/articles/11258 Later versions of the browsers are supported as long as the vendors do not remove or disable functionality that the product relies upon. For browser levels higher than the levels that have been certified with the product, customer support will accept usage-related and defect- related service requests. As with operating system and virtualization environments, if IBM support cannot recreate the issue in our lab, we may ask the client to recreate the problem on a certified browser version in order to determine if a product defect exists. Defects will not be accepted for cosmetic differences between browsers or browser versions that do not affect the functional behavior of the product. If a problem is identified in the product, defects will be accepted. If a problem is identified with the browser, IBM may investigate potential solution or work-around that the client may implement until a permanent solution becomes available. * In IBM Storwize V7000 Unified, quarantined folders are only accessible with the root ID. This restriction will be lifted in a future IBM Storwize V7000 Unified release. Refer to the below technote for more information on this issue: http://www-01.ibm.com/support/docview.wss?uid=ssg1S1004078 For more details please refer to the V1.5.2 Configuration Limits and Restrictions for IBM Storwize V7000 Unified for product restrictions that currently apply: http://www.ibm.com/support/docview.wss?uid=ssg1S1004680 * Updates from release prior to V7.3.0.x to 7.4.0.x will disable the cache when the update starts and the cache will remain disabled until the upgrade completes, at which time it will be automatically re-enabled. * If using IP replication, please review the set of restrictions published in the V7.4 Configuration Limits and Restrictions document. * Intra-Cluster Global Mirror Not Supported Refer to the following flash for more information on this restriction: http://www.ibm.com/support/docview.wss?uid=ssg1S1003725 * SAN Volume Controller Inter-cluster Metro Mirror and Global Mirror Compatibility Cross Reference Refer to the following flash for more information on this restriction: http://www.ibm.com/support/docview.wss?uid=ssg1S1003646 * Systems running V7.4.0.3 without compression should not enable compression. Once the software upgrade process has been started, the management GUI automatically refreshes to display the progress of the upgrade. During the upgrade each file module will be restarted, resulting in a fail-over and fail-back of the management services, including the GUI. After a fail-over has occurred it may be necessary to manually refresh/reload the page in the web browser in order to reconnect with the new active management node and login again. If an IBM Storwize V7000 Unified Code Upgrade Stalls or Fails then contact IBM Support for further assistance http://www.ibm.com/support/docview.wss?uid=ssg1S1002894 -------------------------------------------------------------------------------------- 7. Maximum Configurations The maximum configurations for IBM Storwize V7000 Unified 1.5.2.6 are documented in the V1.5.2.6 Configuration Limits and Restrictions for IBM Storwize V7000 Unified document which is available from: http://www.ibm.com/support/docview.wss?uid=ssg1S1004680#_MaximumConfigurations -------------------------------------------------------------------------------------- 8. Supported Hardware This release of IBM Storwize V7000 Unified software is supported on the following hardware types: File Modules: * 2073-700 * 2073-720 Storwize V7000 Control enclosures: * 2076-112 * 2076-124 * 2076-312 * 2076-324 * 2076-524 Storwize V7000 Expansion enclosures: * 2076-212 * 2076-224 * 2076-12F * 2076-24F --------------------------------------------------------------------------------------- 9. Pre-1.5.2.6 Release Information 9.1 Storwize V7000 Unified version 1.5.2.5 Code Levels: Storwize V7000 Unified Product Version 1.5.2.5(1.5.2.5-12) Storwize V7000 (2076) Product Version 7.4.0.10(103.27.1605260000) Features added and withdrawn in IBM Storwize V7000 Unified File Module 1.5.2.5. None Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.5: (a) Fixes in 1.5.2.5-12 Critical Fixes HU01393 After upgrade to 1.5.2.5-11, some CIFS share users may get 'Permission denied' and 'No space on disk' error messages while accessing files, directories having long ACLs. (b) Fixes in 1.5.2.5-11 Security Fixes For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER) http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified Critical Fixes HU01348 Callhome failure on systems running V1.5.2.4. HU01336 On a busy system, CTDB on one node may become unresponsive for nearly half a minute causing the other nodes to mark it as dead and trigger recovery. This may cause cascading failures and loss of access. HU01337 CTDB had difficulty releasing IP addresses after a node was banned for poor performance. High Importance Fixes HU01311 Restoration of filesystem from TSM backup fails when encountering special character in file or path name. HU01284 Winbind floods the log file with repetitive messages when varonis polls using 'wbinfo -u' and 'wbinfo -g', degrading the system performance. HU01334 After upgrade, 'lsquota' CLI may timeout or not list any output. HU01286 'lstask' reports error for 'BackupMgmtNode' and 'StartRunPolicy'. HU01343 Inheritance from share directory is not disabled while adding the existing inherited permissions due to unresolved SID entries in ACL list. HU01344 Users are not restricted by system while modifying CIFS share ACL from 'FULL' to 'CHANGE'. HU01339 While restarting CTDB, 'service ctdb start' fails unexpectedly. HU01358 The domain admin user may not be able to login to GUI but can login to CLI. HU01273 During node reboot, 'resumenode' CLI fails with false messages stating 'All required Filesystem not mounted' and makes GUI inaccessible. HU01277 GUI displays blank or default values for warning and error threshold for fileset quota. 9.2 Storwize V7000 Unified version 1.5.2.4 Code Levels: Storwize V7000 Unified Product Version 1.5.2.4(1.5.2.4-13) Storwize V7000 (2076) Product Version 7.4.0.9(103.27.1602170000) New features in IBM Storwize V7000 Unified File Module 1.5.2.4: None Features withdrawn in IBM Storwize V7000 Unified File Module 1.5.2.4. With V1.5.2.4, the AoS (Assist On-Site) function used to enable remote login support is withdrawn as the server side infrastructure supporting the AoS client version included in V1.5 of the product is being sunset. The code supporting AoS is removed from V1.5.2.4 and AoS will not function upon upgrading to V1.5.2.4. The AoS function in systems running earlier V1.5.x code levels will stop working when the server infrastructure for this version is sunset. Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.4: Security Fixes For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER) http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified Critical Fixes HU01121 CTDB and NFS monitoring can time out under extensive GPFS calls triggering IP failover. HU01114 When system is overload CTDB can become unresponsive for sometime causing database recovery failure resulting in outage or impacting system performance. HU01129 Client unable to access the system because of CTDB unhealthy on all nodes. HU01150 Process smbd terminates after CTDB timeout. HU01133 Ganesha exits on locks out of sync causing NFS services to stop. HU01168 After upgrade access to CIFS shares is lost on the system when the number of ranges for AUTO ID mapping is less than 3 for plain AD authentication configuration when default configuration settings for AUTO ID pool are overridden. High Importance Fixes HU01128 Excessive CTDB database recoveries impacts system performance. HU01154 Excessive SS0010 and SS0011 events causes GUI to crash. HU01123 Java runs out of memory and generates core dump causing GUI to crash. HU01113 While upgrading V7000 Unified an access outage may occur due to node ban. HU01146 Upgrade failed with error 01A8 at task U020cluster_upgradenode_all. HU01148 System fails Nessus security scan with TCP port 443 and 1081 vulnerabilities. HU01152 Upgrade failed with error 01E4 at task U035cluster_hsm_policy_upgrade. HU01138 Upgrade failed with error 01E0 at task U010cluster_hsm_upgrade. HU01117 After upgrade the lsnwinterface CLI does not display vlan ip information. HU01170 Running nmap makes the CLI server inadvertently process the nmap requests incorrectly eventually leading to CTDB marking the node unhealthy. HU01162 CIFS clients using SEC_FLAG_SYSTEM_SECURITY flag for file open operations unable to access files from CIFS shares. e.g. TSM client from a Windows client system or a setacl operation from a Windows 2012 client. HU01173 Callhome generates multiple cndump logs due to timezone offset difference. HU01175 GPFS mmapplypolicy command failure due to a race condition when several simultaneous policy sessions are invoked through operations such as triggering multiple NDMP backup sessions in parallel. HU01164 GUI is incorrectly displaying fileset quota limits inherited from filesystem even though the 'per fileset' quota option is enabled. HU00978 False warning messages of severe category from GPFS on a busy but healthy system. Suggested Fixes HU01130 Documentation clarification for snapshot behavior. HU01124 If the netbios name matches with AD domain in client infrastructure can lead to access loss. HU01135 Unscannable files are continuously being resent for antivirus scanning which can affect antivirus performance. 9.3 Storwize V7000 Unified version 1.5.2.3 Code Levels: Storwize V7000 Unified Product Version 1.5.2.3(1.5.2.3-14) Storwize V7000 (2076) Product Version 7.4.0.6(103.23.1510130000) New features in IBM Storwize V7000 Unified File Module 1.5.2.3: None Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.3: Critical Fixes HU00960 CTDB crashes resulting in service outage. HU00951 NFS deny access to filesystem in FileModule2. It occurs when runs mmdelns and follows it up with a mmcrnsd for the same disk, causing an assert. HU00938 Deadlock between SMBD and SMBSTATUS can lead to service outage. HU00931 Custom modified SAMBA setting for "VFS OBJECT" of a share, results in in-accessible share after upgrade from 1.4. High Importance Fixes HU00911 Upgrade from 1.4.3 to 1.5.2.1 failed with U035node_update_packages error because of a problem on one node while trying to update yum. HU00958 Replication failure after upgrade from 1.4.X to 1.5.X due to missing registry keys. HU00962 Slow GUI access and frequently temporarily offline GUI. HU00948 SAMBA4 introduced a GPFS winattr query for offline bit to detect change, after every IO. HU00945 After code update from release 1.4.X to release 1.5.X some entries of the active directory server are missing. HU00940 UEFI NMI report parameter prevents NMI requested kdumps from completing. HU00914 File is locked by other user message detected when trying to save files on some CIFS exports. HU00918 updatefs fails with command exception whenever there is an error while its execution. HU00939 Reduce the SMBD locking related messages in syslog and samba logs HU00964 User was not able to create filesets starting with numbers using the GUI. HU00968 CIFS performance is significantly lower on the nodes where the MGMT services are running Suggested Fixes HU00950 Callhome alert description fields are not populated correctly. HU00954 GUI shows hardware components different starting with FW 1.5. HU00933 GUI displays incorrect time for the events. HU00963 Information center 1.5.2 is not correct for the async replication sparse files handling. For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER): http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified 9.4 Storwize V7000 Unified version 1.5.2.2 Code Levels: Storwize V7000 Unified Product Version 1.5.2.2(1.5.2.2-13) Storwize V7000 (2076) Product Version 7.4.0.5(103.23.1507160000) New features in IBM Storwize V7000 Unified File Module 1.5.2.2: None Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.2: High Importance Fixes HU00814 When connect to the Device and special characters are used it can happen that the samba crashes and users got disconnected HU00837 Unexpected IP failover due to an unhealthy CTDB HU00857 Samba performance enhancement HU00859 After code upgrade/reboot a hardware error message is posted "Sensor all PCI error detected a critical state" HU00860 Performance issue when running async replication very frequently HU00863 When the system is overload GPFS state function "mmgestate" times out which can result in lost of access HU00865 Policy status reports error in policy execution HU00867 Interface node crashed caused by how NFS locks is handled HU00868 Syslog get filled with messages like "Incomplete multibyte sequence" HU00877 Lots of smbd core dumps HU00847 Systems may report loss of configuration changes performed earlier after resuming a suspended management. HU00853 Problems with MAC OSX and symbolic links. Suggested Fixes HU00798 When there is a large volume of TSM backup files, the logs or errors won't be displayed by the GUI HU00801 EFSSP0012C Command mkvdisk is not supported on current cluster profile V7000 Unified detected after executing mkvdisk command HU00813 CLI command chstoragesystem causing NullPointerException HU00849 AOS code fails to connect successfully to AOS website HU00851 If a logfile is not trimmed properly this could possibly end up filling up a filesystem HU00855 SFTP service stops working when system settings changed to disable remote domain users to able to login into the system HU00865 During execution of migration policy, the task is reported as failed. This is a false positive message. HU00868 Syslog gets filled with messages like "Incomplete multibyte sequence" HU00871 Filesets view does not display usage capacity in GUI HU00876 /var/log/messages shows thousands of "VFS MAKE CONNECTION FAILED!" HU00879 Following event was reported on the GUI on a passive management node: EFS1F0103C A stopped or failed service was detected with mgmt_backup HU00885 Typo in the documentation for the subject, Upgrading ACLs from Version R1.4.x to R1.5.x HU01010 Upgrade from 1.4.2.0 to 1.5.1.0 failed with error 01BA which is unable to identify software version. This Storwize V7000 Unified 1.5.2.2 release contains security fixes. For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER): http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified 9.5 Storwize V7000 Unified version 1.5.2.1 Code Levels: Storwize V7000 Unified Product Version 1.5.2.1(1.5.2.1-10) Storwize V7000 (2076) Product Version 7.4.0.4(103.23.1504140000) New features in IBM Storwize V7000 Unified File Module 1.5.2.1: None Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.1: High Importance Fixes HU00738 Samba-Clients can register themselves to be notified when a change happens on a File/Folder. These registrations (locks) are not removed upon deletion of a folder and therefore cause problems for the client holding the lock HU00741 Creation a Filesystem, whose name starts with the same string as that of an existing Filesystem with active exports, causes CTDB to fail HU00750 If snapshots were deleted with regular GPFS commands, the CLI/GUI does not get informed about the change HU00753 Deletion of the predefined Admin user causes the code update to fail HU00758 V7000 Unified 1.5.2.0 may be affected by LEAP seconds HU00767 If a File or Foldername contains spaces recall operations might fail HU00768 CIFS exports getting reactivated before the filesystem is mounted under certain conditions may get removed by the SambaRefreshTask HU00776 Async replication issue when new network route is added HU00778 The Errno 13 occurs when a fileset is setup and unwanted user walk through it HU00779 LDAP configuration with 'sslMode' set to TLS fails with error message "Confidentiality required (result: 13)" HU00780 CIFS Share becomes inaccessible in Local Authentication configuration HU00781 mkdisk fails with error EFSSG0476C/EFSSG0565W when NSD is created from CLI/GUI HU00784 Prepopulation fails on cache site in remote caching setup HU00787 Running prepopulation on cache cluster causes the home cluster "\" to fill Suggested Fixes HU00771 cnrscallhomeutil -l in cndump shows incorrect type-mod of V7000 HU00773 CLI/GUI command lsuser does not work HU00782 Unable to create export from a snapshot through GUI This Storwize V7000 Unified 1.5.2.1 release contains security fixes. For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER): http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified 9.6 Storwize V7000 Unified version 1.5.2.0 Code Levels: Storwize V7000 Unified Product Version 1.5.2.0(1.5.2.0-39) Storwize V7000 (2076) Product Version 7.4.0.3(103.23.1503140000) New features in IBM Storwize V7000 Unified File Module 1.5.2.0: * New event generated for Emulex UE message detected Issues resolved in IBM Storwize V7000 Unified File Module 1.5.2.0: Critical Fixes HU00639 Samba is performing additional access checks in user space which require UID/GID to SID mappings. Mappings for non-existent users are not cached, which results in excessive LDAP queries HU00643 Huge amount of non delivered Callhomes prevent the GUI to start HU00692 The user is not informed about the meta data or data not being evenly replicated among the selected storage pools when creating a file system with some form of replication enabled HU00705 After upgrade from V7KU 1.4 to 1.5 level, while running the updatefs command, the created exports may vanish HU00683 CTDB managed IP addresses, network and the authentication configurations problems after changing the NetBios name with CLI command "cfgcluster". Additionally all exports/shares can get lost HU00696 Transient false positive MMFS_FSSTRUCT error code 1124 messages can be misleading HU00702 After an unexpected power outage file system corruption is detected and the file system check (MMFSCK) fails to correct it HU00713 There is a problem observed with large number of samba connections causes CIFS access loss, CTDB locking messages and GPFS long waiters High Importance Fixes HU00652 Connectivity checks between IBM Storage and the clients Active Directory fail every 10 hours generating error messages on the GUI HU00663 Improved logging for CTDB in failure scenarios HU00690 There is no information listed about the quotas created on the system in Files -> Quotas section in the GUI when there are too many quotas created HU00692 Due to an Emulex driver issue whenever the Emulex NIC card on a file module experiences an Unrecoverable Error (UE) it does not mark the link down HU00707 Incorrect failure message display if a backup job finishes with failure "ssh: Could not resolve hostname fgrep -q ANS1311E" HU00712 After upgrading to 1.5.x, access to shares may be lost of ID range does not have space for 3 range buckets HU00639 Changes in Samba can cause a non translatable UIDs to query the LDAP Server for exports/shares holding lots of files HU00700 Upon suspending a node CTDB on the other nodes in the cluster go into unreachable state HU00682 Replication fails with "Path_name too long" error causes impact on further backup of async processes HU00714 Snapshot delete time out for large snapshot resulting in an orphan snapshot though snapshot is deleted from GPFS HU00715 After upgrade to 1.5.x, extended read/write attributes are strictly enforced on the file system. Such strict enforcement can result into access loss as behavior is as per standards HU00727 Error detected after trying to start an upgrade caused by Software Upgrade Test Utility HU00730 CIFS client observes session drop every 10 hours HU00724 Network access problems detected after upgrade Suggested Fixes HU00687 File change notifications between two separate clustered systems in ACE setups are not supported with SMB clients HU00641 If the cron task BackupMmgtNode is not configured at all or is disabled no notification is issued HU00685 The speed information of the virtual network adapter is missing when the bonding mode is 802.3ad (4) after an upgrade HU00686 While activating the exports after an upgrade the "chexport --active" throws NullPointerException message HU00687 Filechange notifications between two separate clustered systems in ACE setups are not supported with SMB clients This Storwize V7000 Unified 1.5.2.0 release contains security fixes. For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link(HIPER): http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified 9.7 Storwize V7000 Unified version 1.5.1.3 Code Levels: Storwize V7000 Unified Product Version 1.5.1.3(1.5.1.3-2) Storwize V7000 (2076) Product Version 7.4.0.2(103.21.1412180000) New features in IBM Storwize V7000 Unified File Module 1.5.1.3: None Issues resolved in IBM Storwize V7000 Unified File Module 1.5.1.3: Critical Fixes HU00633 NFS Ganesha server fails file create requests from AIX or Irix clients under certain conditions. HU00632 Can not download the logs from the GUI, the Download Support Package button will open the download task progress dialog but the dialog will stall Suggested Fixes HU00631 The Real information is not correctly displayed in the capacity pod in the GUI. The storage pod shows 0 regardless of the real value This Storwize V7000 Unified 1.5.1.3 release contains security fixes. For more information on the security fixes please refer to the flashes with "Security Bulletin:" in heading at below link: http://www-947.ibm.com/support/entry/portal/alerts/hardware/system_storage/disk_systems/mid-range_disk_systems/ibm_storwize_v7000_unified 9.8 Storwize V7000 Unified version 1.5.1.2 Code Levels: Storwize V7000 Unified Product Version 1.5.1.2(1.5.1.2-1) Storwize V7000 (2076) Product Version 7.4.0.2(103.21.1412180000) New features in IBM Storwize V7000 Unified File Module 1.5.1.2: None Issues resolved in IBM Storwize V7000 Unified File Module 1.5.1.2: None 9.9 Storwize V7000 Unified version 1.5.1.1 Code Levels: Storwize V7000 Unified Product Version 1.5.1.1(1.5.1.1-7) Storwize V7000 (2076) Product Version 7.4.0.1(103.21.1412100000) New features in IBM Storwize V7000 Unified File Module 1.5.1.1: Supports block level Encryption for file system volumes (when using Storwize V7000 Gen 2 as back-end storage). This feature is not available when Storwize V7000 Gen 1 used as back-end storage. Issues resolved in IBM Storwize V7000 Unified File Module 1.5.1.1: Critical Fixes HU00624 updatefs CLI command fails when --aclpath parameter is used and the sharename contains spaces HU00627 CTDB failover caused by the following event: "GPFS ERROR - MMGETSTATE FAILED WITH ERROR CODE -10" 9.10 Storwize V7000 Unified version 1.5.1.0 Code Levels: Storwize V7000 Unified Product Version 1.5.1.0(1.5.1.0-39) Storwize V7000 (2076) Product Version 7.4.0.0(103.20.1411220000) New features in IBM Storwize V7000 Unified File Module 1.5.1.0: None APARs resolved in IBM Storwize V7000 Unified File Module 1.5.1.0: Critical Fixes HU00523 After a node failover few exports become inactive by going into "false-unmounted" state and due to insufficient debug logging available development cannot root-cause such issues HU00531 During remote caching if files or folders are renamed then under high workloads GPFS asserts on the nodes HU00598 On executing 'updatefs --aclmode show' CLI command, the ACL mode returns inconsistent. This happens when the system has inactive shares configured HU00560 'cfglocalauth' CLI command fails to configure the system authentication after running cfglcuter in a system that was already configured with localauth HU00512 Users lose access to files and folders after the administrator changes the password on the AD Server HU00615 GPFS long waiters lead to service outage on a node High Importance Fixes HU00551 Restoration of backed up files fail when using the GUI. The failure happens as we are unable to provide the seconds in the restore dialogue HU00604 An iSeries CIFS client system cannot access the shares HU00588 After a code upgrade to V1.5.0.0 the snapshots created cannot be accessed by windows clients HU00570 Generation of support package fails with error "EFSSG0475C Error in executing Storage System command svcwrapper" HU00555 The /var filesystem fills up due to a sparse file used by the local authentication. This mostly happens if the system has very large valued UID numbers HU00617 ASU PS RAS checkout call does not use -kcs parameter. This affects CPU utilization HU00554 Asynchronous replication fails with error code EE_INTERNAL due to broken hard links. This happens if the replication is configured with no source side snapshot option HU00583 IP report in the GUI shows blank values for canister IPs of V7000 HU00567 No callhome generated after system reported local HDD event HU00621 Asynchronous replication exits with internal error when a new replication job is started for a replication about to complete Suggested Fixes HU00577 Restore files job are shown as backup jobs in the GUI. This leads to confusion as it is not clear as to what kind of job is running HU00569 Knowledge Center page on the VLAN installation guide needs to be updated HU00572 The backup notification sends an email notification twice after backup is completed HU00558 Incorrect man page documentation provided in Knowledge Center for 'lspool' CLI command HU00576 The network section in the GUI shows a misleading state for degraded network interfaces HU00585 Instead of sending one daily mail summary, the system is sending too many summary mails in one day HU00534 CLI command 'lshsm' provides wrong unit while displaying the output HU00581 Event log gets filled with "Consistency check done on VD" informational messages which causes real errors to be overlooked HU00619 Information about configuring local authentication is missing from the releases V7000 Unified 1.4.3 and 1.5.0 in Knowledge Center 9.11 APARs resolved in previous Storwize V7000 7.4.x releases: 7.4.0.9 Suggested HU00831 Single node assert due to hung IO caused by cache deadlock. HU01029 After boot drive replacement on a DH8 the node may assert when user logs in as superuser using CLI to service IP or service GUI. 7.4.0.5 HIPER HU00725 When a secondary site does not have a secondary volume defined a data access issues can occur when adding a Global Mirror Change Volume relationship to a consistency group on the primary site. Critical HU00671 1691 error on arrays when using multiple FlashCopies of the same source. HU00820 Consistency data issue when using encrypted arrays. HU00811 SAN connectivity problems can lead to a backend controller being detected as incorrect type causing data access issues High Importance HU00825 Java exception error when using the Service Assistant GUI to complete an enclosure replacement procedure HU00659 Global Mirror with Change Volumes freeze time reported incorrectly HU00673 Drive slot is not recognized by the following 'drive auto manage' procedure HU00731 Single node assert due to invalid vdisk memory allocation pointer Suggested HU00711 GUI response slow when filtering a large number of volumes HU00829 1125 (or 1066 on V7000 Generation 2) events incorrectly logged for all PSU's/Fan trays when there is a single PSU/fan tray fault 7.4.0.4 HIPER HU00680 Compressed volumes go offline due to false detection event. Applies to V7000 Generation 2 systems only running V7.3.0.9 or V7.4.0.3 High Importance HU00676 Node assert due to compression engine restart 7.4.0.3 Critical Fixes HU00645 Loss of access to data when using compressed volumes on 7.4.0.1 can occur when there is a large number of consecutive and highly compressible writes to a compressed volume HIPER HU00654 Loss of access to data when FlashCopy stuck during a Global Mirror Change Volumes cycle Critical HU00669 Node assert and VMware host IO timeouts if a node is removed from the cluster during upgrade from a pre V7.4.0 version to V7.4.0 whilst there are active VAAI CAW commands High Importance HU00516 Node assert due to software thread deadlock HU00629 Performance degradation triggered by specific IO pattern when using compressed volumes due to optimization issue HU00630 Temporary loss of paths for FCoE hosts after 497 days uptime due to FCoE driver timer problem HU00637 HP MSA P2000 G3 controllers running a firmware version later than TS240P003 may not be recognized by SVC/Storwize HU00646 Easy tier throughput reduced due to Easy tier only moving 6 extents per 5 minutes regardless of extent size HU00653 1691 RAID inconsistencies falsely reported due to RAID incomplete locking issue HU00665 Node assert due to software thread deadlock condition during execution of internal mdisk/discovery process HU00666 Upgrade to V7.4.0 stalls due to dependent vdisks HU00672 Node assert due to compression stream condition HU00677 Node assert or loss of access to GUI/CLI due to defunct SSH processes II14771 Node assert due to compression/index re-writing timing condition Suggested HU00389 When a Storwize system is configured as a backend storage subsystem for an SVC or another Storwize system, the port statistics count the traffic between these two systems as remote cluster traffic instead of host to storage traffic (e.g. in TPC 'Port to Remote Node Send Data Rate' instead of 'Port to Controller Send Data Rate') HU00678 iSCSI hosts incorrectly show an offline status following update to V6.4 from a pre V6.4 release 7.4.0.2 * Encrypted data at rest for Storwize V7000 Gen 2 * Support for 4096 byte native drive blocksize Critical Fixes HU00645 Loss of access to data when using compressed volumes on 7.4.0.1 can occur when there is a large number of consecutive and highly compressible writes to a compressed volume 7.4.0.1 * Encrypted data at rest for Storwize V7000 Gen 2 * Support for 4096 byte native drive blocksize 7.4.0.0 * Increased parallelism for Compression, providing further improved performance on 2145-DH8 and Storwize V7000 Gen 2 * Support for 16 Gb/s Fibre Channel on 2145-DH8 and Storwize V7000 Gen 2, for installation & configuration guidelines see Technote * Global Mirror maximum supported round trip latency between systems increased to 250ms * Additional Data Integrity validation using T10DIF for data stored on drives for Storwize V7000 Gen 2 * The lssoftwareupgradestatus command has been removed, and replaced with a more detailed lsupdate command. This provides more visibility of the update status. A limited version of this command will become available as soon as the configuration node is running the V7.4 or later. * The term "upgrade" is being replaced with "update" HIPER HU00546 Multiple node asserts when attempting to access data beyond the end f the volume IC80230 Both nodes assert die to Ethernet storm Critical Fixes HU00505 Multiple node asserts caused by timing window when using inter-system replication HU00518 Multiple Node Asserts due to invalid SCSI commands generated by network probes HU00544 Storage pool offline when upgrading firmware on storage subsystems listed in APAR Environment HU00545 Loss of Access to data after control chassis or midplane enclosure replacement High Importance Fixes HU00219 Node Assert due to timing window when a FlashCopy map is being deleted HU00490 Node assert when using Metro Mirror or Global Mirror HU00494 Node Assert caused by timing window when handling XCOPY commands HU00520 Node Assert caused by iSCSI command being aborted immediately after the command is issued HU00528 Single PSU DC output turned off when there is no PSU hardware fault present HU00538 Node assert when removing hostport (via GUI or CLI) when there is outstanding IO to host HU00543 Elongated IO pause when starting or stopping remote copy relationships when there are a large number of remote copy relationships HU00547 IO delay during site failure using enhanced stretched cluster Suggested Fixes HU00130 Node assert due to IPC queue state HU00251 Unable to migrate vdisk mirror copies to alternate storage pool using GUI HU00300 Volume mirroring synchronization exceeds the maximum copy rate HU00305 System unable to detect and use newly added ports on EMC VMAX HU00467 Global Mirror Change Volumes Freeze time not reported correctly if cycle takes longer than the cycle period to complete HU00540 Configuration Backup fails due to invalid volume names HU00541 Fix Procedure fails to complete successfully when servicing PSU HU00487 Rebuild process stalls or unable to create mdisk due to unexpected RAID scrub state HU00548 Unable to create IP partnership that had previously been deleted ----------------------------------------------------------------------------------------------------