This package provides firmware for Power 770 (9117-MMB)  and Power 780 (9179-MHB)  servers only.

The firmware level in this package is:

1.1 Minimum HMC Code Level

This section is intended to describe the "Minimum HMC Code Level" required by the System Firmware to complete the firmware installation process. When installing the System Firmware, the HMC level must be equal to or higher than the "Minimum HMC Code Level" before starting the system firmware update.  If the HMC managing the server targeted for the System Firmware update is lower than the "Minimum HMC Code Level" the firmware update will not proceed.

The Minimum HMC Code level for this firmware is:  HMC V7 R7.1.0 Service Pack 2 (PTF MH01219) or higher.

For information concerning HMC releases and the latest PTFs,  go to the following URL to access Fix Central.
http://www-933.ibm.com/support/fixcentral/

NOTE: You must be logged in as hscroot in order for the firmware installation to complete correctly.

2.0 Cautions and Important Information

2.1 Cautions

Downgrading firmware from any given release level to an earlier release level is not recommended.
If you feel that it is necessary to downgrade the firmware on your system to an earlier release level, please contact your next level of support.

WARNING
For servers with a single CEC enclosure running AM720_xxx_yyy, attempts to downgrade firmware to AM710_065_043, AM710_083_043, or AM710_086_043 will not complete successfully.  The managing HMC will lose its connection with the server and manual intervention will be required to complete the installation. To correct this condition reference the below link, or contact your hardware support representative.

http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/AM720-AM710-Dgrd_Rcvry.html


2.2 Important Information

IPv6 Support and Limitations

IPv6 (Internet Protocol version 6) is supported in the System Management Services (SMS) in this level of system firmware. There are several limitations that should be considered.

When configuring a network interface card (NIC) for remote IPL, only the most recently configured protocol (IPv4 or IPv6) is retained. For example, if the network interface card was previously configured with IPv4 information and is now being configured with IPv6 information, the IPv4 configuration information is discarded.

A single network interface card may only be chosen once for the boot device list. In other words, the interface cannot be configured for the IPv6 protocol and for the IPv4 protocol at the same time.

Concurrent Firmware Updates

Concurrent system firmware update is only supported on HMC Managed Systems only.

Memory Considerations for Firmware Upgrades

The increase in memory used by the firmware is due to the additional functionality in later firmware releases.

3.0 Firmware Information and Description

Use the following examples as a reference to determine whether your installation will be concurrent or disruptive.

For systems that are not managed by an HMC, the installation of system firmware is always disruptive.

Note: The concurrent levels of system firmware may, on occasion, contain fixes that are known as deferred. These deferred fixes can be installed concurrently, but will not be activated until the next IPL. Deferred fixes, if any, will be identified in the "Firmware Update Descriptions" table of this document. For deferred fixes within a service pack, only the fixes in the service pack which cannot be concurrently activated are deferred.

Note: The file names and service pack levels used in the following examples are for clarification only, and are not necessarily levels that have been, or will be released.

System firmware file naming convention:

01AMXXX_YYY_ZZZ

NOTE: Values of service pack and last disruptive service pack level (YYY and ZZZ) are only unique within a release level (XXX). For example, 01AM720_067_045 and 01AM740_067_053 are different service packs.

An installation is disruptive if:

Example: Currently installed release is AM710, new release is AM720 Example: AM720_120_120 is disruptive, no matter what level of AM720 is currently
installed on the system Example: Currently installed service pack is AM720_120_120 and new service pack is AM720_152_130

An installation is concurrent if:

The release level (XXX) is the same, and
The service pack level (YYY) currently installed on the system is the same or higher than the last disruptive service pack level (ZZZ) of the service pack to be installed.

Example: Currently installed service pack is AM720_126_120,  new service pack is AM720_143_120.

Firmware Information and Update Description

 
Filename Size Checksum
01AM710_083_043.rpm 25880393
20545

Note: The Checksum can be found by running the AIX sum command against the rpm file (only the first 5 digits are listed).
ie: sum 01AM710_083_043.rpm

AM710
For Impact, Severity and other Firmware definitions, Please refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
AM710_083_043

06/07/10
Impact:  Serviceability          Severity:  ATT

System firmware changes that affect all systems

  • The firmware was enhanced to dynamically update the IPL speed on the control (operator) panel when the IPL speed is changed by another method.
  • A problem was fixed that caused the service processor to crash with SRC B181720D due to an out-of-memory condition.
  • A problem was fixed that caused SRC B113E504 SRCs with a description of "Undefined Error Code" to be erroneously logged. 
  • The firmware was enhanced such that if a memory controller fails or overheats, the memory controller/DIMM will be called out rather than the processor card.
  • Two problems were fixed that caused SRCs B181B8F8 and SCR B181B86A to be erroneously logged during a mainstore dump.  In both cases, the SRC being logged prevented the mainstore dump data from being collected and erroneously called out hardware for replacement.
  • A problem was fixed the prevented the reset/reload bit from being set correctly in a service processor error log entry.
  • A problem was fixed that caused a call home to be erroneously made with SRC B181E911, and a service processor dump to be taken unnecessarily.
  • A problem was fixed that caused the HMC to show a status of "Incomplete" for the managed system, and numerous service processor dumps to be generated.
System firmware changes that affect certain systems
  • PARTITION-DEFERRED:  A problem was fixed that caused SRC BA210000 to be erroneously logged on the target system when a partition was moved (using Live Partition Mobility) from a Power7 system to a Power6 system.
  • A problem was fixed that caused SRC BA280000 to be erroneously logged on the target system when a partition was moved (using Live Partition Mobility) from a Power7 system to a Power6 system.
  • On systems with the Active Energy Manager in IBM Director activated, a problem was fixed that caused a small error in the processor usage calculations.
  • On systems with redundant service processors, a problem was fixed that caused SRC B181E617 to be erroneously logged and a service processor dump to be unnecessarily generated.
  • A problem was fixed that caused a system or partition running Linux to crash when the "serv_config -l" command was run.
  • On systems in an i5/OS clustering configuration, a problem was fixed that prevented a partition in an I/O pool from being deleted.
AM710_065_043

03/16/10
Impact:  New            Severity:  New

GA Level


4.0 How to Determine Currently Installed Firmware Level

For HMC managed systems:  From the HMC, select Updates in the navigation (left-hand) pane, then view the current levels of the desired server(s).

Alternately, use the Advanced System Management Interface (ASMI) Welcome pane. The current server firmware  appears in the top right corner. Example: AM710_yyy.


5.0 Downloading the Firmware Package

 You must read and agree to the license agreement to obtain the firmware packages.

Note: If your HMC is not internet-connected you will need to download the new firmware level to a CD-ROM or ftp server.


6.0 Installing the Firmware

The method used to install new firmware will depend on the release level of firmware which is currently installed on your server. The release level can be determined by the prefix of the new firmware's filename.

Example: AMXXX_YYY_ZZZ

Where XXX = release level


For details on installing the firmware, perform the following steps:

1. Go to the IBM Power System Hardware Information Center at:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp

2. Select the platform and model you are working with.

3. Select from the following options: 

IBM i Systems

See "Server Firmware and HMC Wizard",
http://www-912.ibm.com/s_dir/slkbase.nsf/recommendedfixes

7.0 Change History


Date Description
Oct 06, 2010 - Added Cautions section 2.1 with Downgrade warnings.
- Other minor documentation updates