Power6 Mid-Range Firmware

Applies to: 9117-MMA , 9406-MMA, and 8234-EMA

This document provides information about the installation of Licensed Machine or Licensed Internal Code, which is sometimes referred to generically as microcode or firmware.


Contents


1.0 Systems Affected

This package provides firmware for System p 570 (9117-MMA), System i570 (9406-MMA), Power 570 (9117-MMA), and Power 560 (8234-EMA) servers only.

The firmware level in this package is:

1.1 Minimum HMC Code Level

This section is intended to describe the "Minimum HMC Code Level" required by the System Firmware to complete the firmware installation process. When installing the System Firmware, the HMC level must be equal to or higher than the "Minimum HMC Code Level" before starting the system firmware update.  If the HMC managing the server targeted for the System Firmware update is running a code level lower than the "Minimum HMC Code Level" the firmware update will not proceed.

The Minimum HMC Code level for this firmware is:  HMC V7 R3.5.0 Service Pack 1 ( PTF MH01212) and MH01217 (or higher).

Although the Minimum HMC Code level for this firmware is listed above,  HMC level V7 R3.5.0 with PTF MH01238 (Service Pack 3), or higher is suggested for this firmware level.

For specific fix level information on key components of IBM Power Systems running the AIX, IBM i and Linux operating systems, we suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home

For information concerning HMC releases and the latest PTFs,  go to the following URL to access Fix Central.
http://www-933.ibm.com/support/fixcentral/

NOTE: You must be logged in as hscroot in order for the firmware installation to complete correctly.

1.2 Minimum SDMC Code Level

This section is intended to describe the "Minimum Systems Director Management Console (SDMC) Code Level" required by the System Firmware to complete the firmware installation process. When installing the System Firmware, the SDMC level must be equal to or higher than the "Minimum SDMC Code Level" before starting the system firmware update.  If the SDMC managing the server targeted for the System Firmware update is running a code level lower than the "Minimum SDMC Code Level" the firmware update will not proceed.

The Minimum SDMC Code level for this firmware is:  SDMC V6 R7.3.0 with Mandatory PTF MF53082.

For information concerning SDMC releases and the latest PTFs,  go to the following URL to access Fix Central:
http://www-933.ibm.com/support/fixcentral/

For specific fix level information on key components of IBM Power Systems running the AIX, IBM i and Linux operating systems, we suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home


2.0 Cautions and Important Information

2.1 Cautions

Downgrading firmware from any given release level to an earlier release level is not recommended.
If you feel that it is necessary to downgrade the firmware on your system to an earlier release level, please contact your next level of support.

Upgrading from EM320_031 to EM350_xxx

If your current level of firmware is EM320_031 you must install any higher level of EM320 before upgrading your firmware to this level.

Upgrading from EM310_xxx to EM350_yyy

If your current level of firmware is EM310_xxx,  you must install EM320_040 or higher before upgrading your firmware to this level.

2.2 Important Information

IPv6 Support and Limitations

IPv6 (Internet Protocol version 6) is supported in the System Management Services (SMS) in this level of system firmware. There are several limitations that should be considered.

When configuring a network interface card (NIC) for remote IPL, only the most recently configured protocol (IPv4 or IPv6) is retained. For example, if the network interface card was previously configured with IPv4 information and is now being configured with IPv6 information, the IPv4 configuration information is discarded.

A single network interface card may only be chosen once for the boot device list. In other words, the interface cannot be configured for the IPv6 protocol and for the IPv4 protocol at the same time.

Memory Considerations for Firmware Upgrades

The increase in memory used by the firmware is due to the additional functionality in later firmware releases.


3.0 Firmware Information and Description

Use the following examples as a reference to determine whether your installation will be concurrent or disruptive.

For systems that are not managed by an HMC or SDMC, the installation of system firmware is always disruptive.

Note: The concurrent levels of system firmware may, on occasion, contain fixes that are known as Deferred and/or Partition-Deferred. Deferred fixes can be installed concurrently, but will not be activated until the next IPL. Partition-Deferred fixes can be installed concurrently, but will not be activated until a partition reactivate is performed.  Deferred and/or Partition-Deferred fixes, if any, will be identified in the "Firmware Update Descriptions" table of this document. For these types of fixes (Deferred and/or Partition-Deferred) within a service pack, only the fixes in the service pack which cannot be concurrently activated are deferred.

Note: The file names and service pack levels used in the following examples are for clarification only, and are not necessarily levels that have been, or will be released.

System firmware file naming convention:

01EMXXX_YYY_ZZZ

NOTE: Values of service pack and last disruptive service pack level (YYY and ZZZ) are only unique within a release level (XXX).

For example, 01EM310_067_045 and 01EM320_067_053 are different service packs.

An installation is disruptive if:

Example: Currently installed release is EM310, new release is EM320 Example: EM310_120_120 is disruptive, no matter what level of EM310 is currently
installed on the system Example: Currently installed service pack is EM310_120_120 and
new service pack is EM310_152_130

An installation is concurrent if:

Example: Currently installed service pack is EM310_126_120,
new service pack is EM310_143_120.

Firmware Information and Update Description

For information about previous firmware release levels, see  Section 7.0 Firmware History.

 
Filename Size Checksum
01EM350_108_038.rpm 24018865
29340

Note: The Checksum can be found by running the AIX sum command against the rpm file (only the first 5 digits are listed).
ie: sum 01EM350_108_038.rpm

EM350
For Impact, Severity and other Firmware definitions, Please refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
EM350_108_038

07/07/11

Impact:  Availability      Severity:  HIPER - High Impact/PERvasive, Should be installed as soon as possible.

System firmware changes that affect all systems
  • A problem was fixed that caused some of the extended error log data to be parsed incorrectly.  This problem only occurs on systems with a large number of deconfigured components.
System firmware changes that affect certain systems
  • HIPER:  On systems running VIOS, a problem was fixed that caused the system to crash with SRC B700F103.
  • On systems running shared processor partitions, a problem was fixed that caused a partition to hang until powered off and back on.

4.0 How to Determine Currently Installed Firmware Level

For HMC managed systems:  From the HMC, select Updates in the navigation (left-hand) pane, then view the current levels of the desired server(s).

For SDMC managed systems:  From the SDMC Welcome page, select the desired server(s), then select Release Management, then select Power System Firmware Management. Click Gather Target Information, then view the current levels of the desired server(s). 
NOTE:  If Inventory has not previously been collected, a message will be displayed indicating to "View and Collect Inventory" to proceed.

Alternately, you can view the server's current firmware level on the Advanced System Management Interface (ASMI) Welcome pane. It appears in the top right corner. Example: EM350_038.


5.0 Downloading the Firmware Package

Follow the instructions on Fix Central. You must read and agree to the license agreement to obtain the firmware packages.

Note: If your HMC or SDMC is not internet-connected you will need to download the new firmware level to a CD-ROM or ftp server.


6.0 Installing the Firmware

The method used to install new firmware will depend on the release level of firmware which is currently installed on your server. The release level can be determined by the prefix of the new firmware's filename.

Example: EMXXX_YYY_ZZZ

Where XXX = release level


Instructions for installing firmware updates and upgrades can be found at http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/ipha1/updupdates.htm

IBM i Systems

See "Server Firmware and HMC Wizard",
http://www-912.ibm.com/s_dir/slkbase.nsf/recommendedfixes

7.0 Firmware History

The Firmware History can be reviewed at the following url:

http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/EM-Firmware-Hist.html