Power6 High-End System Firmware
Applies to: 9119-FHA
This document provides information about the installation of
Licensed
Machine or Licensed Internal Code, which is sometimes referred to
generically
as microcode or firmware.
Contents
1.0 Systems Affected
This package provides firmware for Power 595 (9119-FHA) Servers
only.
The firmware level in this package is:
1.1 Minimum HMC Code Level
This section is intended to describe the "Minimum HMC Code Level"
required by the System Firmware to complete the firmware installation
process. When installing the System Firmware, the HMC level must be
equal to or higher than the "Minimum HMC Code Level" before starting
the system firmware update. If the HMC managing the server
targeted for the System Firmware update is running a code level lower
than the "Minimum HMC
Code Level" the firmware update will not proceed.
The Minimum HMC Code level for
this firmware is: HMC V7 R3.5.0
Service Pack 1 ( PTF
MH01212) and
MH01217.
Although the Minimum HMC Code level for this firmware is listed
above, HMC level V7 R3.5.0 with PTF MH01238
(Service Pack 3) and MH01259 (Fix for V7 R3.5.0 SP3), or
higher is
suggested for
this
firmware level.
For specific fix level information on key components of IBM
Power Systems running the AIX, IBM i and Linux operating systems, we
suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home
For information concerning HMC releases and the latest PTFs,
go
to the following URL to access Fix Central.
http://www-933.ibm.com/support/fixcentral/
NOTE: You must be logged in as hscroot in order for the
firmware
installation to complete correctly.
1.2 Minimum SDMC Code
Level
This section is intended to describe the "Minimum Systems Director
Management Console (SDMC) Code Level"
required by the System Firmware to complete the firmware installation
process. When installing the System Firmware, the SDMC level must be
equal to or higher than the "Minimum SDMC Code Level" before starting
the system firmware update. If the SDMC managing the server
targeted for the System Firmware update is running a code level lower
than the "Minimum SDMC
Code Level" the firmware update will not proceed.
The Minimum SDMC Code level for
this firmware is: SDMC V6
R7.3.0 with Mandatory PTF MF53082.
Although the Minimum SDMC Code level for this firmware is listed
above, SDMC level V6 R7.3.0 with PTFs MF53082, MF53525 and MF53657, or
higher is suggested for
this
firmware level.
For information concerning SDMC releases and the latest PTFs,
go
to the following URL to access Fix Central:
http://www-933.ibm.com/support/fixcentral/
For specific fix level
information on key components of IBM
Power Systems running the AIX, IBM i and Linux operating systems, we
suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home
2.0
Cautions and Important Information
2.1 Cautions
Downgrading firmware from any
given release level to an earlier release level is not recommended.
If you feel that it is
necessary to downgrade the firmware on
your system to an earlier release level, please contact your next level
of support.
2.2 Important Information
IPv6 Support and Limitations
IPv6 (Internet Protocol version 6) is supported in the System
Management
Services (SMS) in this level of system firmware. There are several
limitations
that should be considered.
When configuring a network interface card (NIC) for remote IPL, only
the most recently configured protocol (IPv4 or IPv6) is retained. For
example,
if the network interface card was previously configured with IPv4
information
and is now being configured with IPv6 information, the IPv4
configuration
information is discarded.
A single network interface card may only be chosen once for the boot
device list. In other words, the interface cannot be configured for the
IPv6 protocol and for the IPv4 protocol at the same time.
Memory Considerations for Firmware Upgrades
The increase in memory used by the firmware is due to the additional
functionality
in later firmware releases.
3.0 Firmware
Information
and Description
Use the following examples as a reference to determine whether your
installation
will be concurrent or disruptive.
Note: The concurrent levels
of system firmware may, on occasion,
contain
fixes that are known as Deferred and/or Partition-Deferred. Deferred
fixes can be installed
concurrently, but will not be activated until the next IPL.
Partition-Deferred fixes can be installed concurrently, but will not be
activated until a partition reactivate is performed. Deferred
and/or Partition-Deferred
fixes,
if any, will be identified in the "Firmware Update Descriptions" table
of this document. For these types of fixes (Deferred and/or
Partition-Deferred) within a service pack, only the
fixes
in the service pack which cannot be concurrently activated are
deferred.
Note: The file names and service pack levels used in the
following
examples are for clarification only, and are not necessarily levels
that
have been, or will be released.
System firmware file naming convention:
01EHXXX_YYY_ZZZ
- XXX is the release level
- YYY is the service pack level
- ZZZ is the last disruptive service pack level
NOTE: Values of service pack and last disruptive service pack
level
(YYY and ZZZ) are only unique within a release level (XXX).
For
example,
01EH330_067_045 and 01EH340_067_053 are different service
packs.
An installation is disruptive if:
- The release levels (XXX) are different.
Example: Currently installed release is EH330, new release is EH340
- The service pack level (YYY) and the last disruptive
service
pack level (ZZZ) are the same.
Example: EH330_120_120 is disruptive, no matter what level of EH330 is
currently
installed on the system
- The service pack level (YYY) currently installed on the system is
lower
than the last disruptive service pack level (ZZZ) of the service pack
to
be installed.
Example: Currently installed service pack is EH330_120_120 and
new service pack is EH330_152_130
An installation is concurrent if:
- The release level (XXX) is the same, and
- The service pack level (YYY) currently installed on the
system
is
the same or higher than the last disruptive service pack level
(ZZZ)
of the service pack to be installed.
Example: Currently installed service pack is EH330_126_120,
new service pack is EH330_143_120.
Firmware Information and Update Description
For information about previous firmware release levels, see Section
7.0 Firmware History
Filename |
Size |
Checksum |
01EH350_120_038.rpm |
37069234
|
60553
|
Note: The Checksum can be found by running the AIX sum command against the rpm file
(only the first 5 digits are listed).
ie: sum 01EH350_120_038.rpm
EH350
For Impact, Severity and other Firmware definitions, Please
refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
|
EH350_120_038
11/09/11
|
Impact: Availability
Severity: HIPER - High Impact/PERvasive, Should be installed as soon as
possible.
System firmware changes that
affect all systems
- A problem was fixed that
caused the system to terminate when rebooting after the power was
removed, then reapplied.
- A problem was fixed that
caused the message "IPL: 500 - Internal Server Error" to be displayed
when the Hardware Management Console option was selected (which is
under the System Information option) on the Advanced System Management
Interface (ASMI).
- On systems running more than
100 logical partitions, a problem was fixed that caused a concurrent
firmware installation to fail.
- A problem was fixed that caused a system's partition
dates to revert back to 1969 after the service processor or its battery
was replaced. This occurred regardless of whether or not the
service processor's time-of-day (TOD) clock was correctly set during
the service action.
- A problem was fixed that
caused a partition migration operation to abort when the partition has
more than 4096 virtual slots.
- A problem was fixed that
caused the message "500 - Internal Server Error." to be displayed when
a setting was changed on the Advanced System Management Interface's
(ASMI's) power on/off menu, when the change was attempted when the
system was powering down.
- A problem was fixed that
caused booting or installing a partition or system from a USB device to
fail with error code BA210012. This usually occurs when an
operating system (OS) other than the OS that is already on the
partition or system is being booted or installed.
- On the System Management
Services (SMS) remote IPL (RIPL) menus, a problem was fixed that caused
the SMS menu
to continue to show that an Ethernet device is configured for iSCSI,
even though the user has changed it to BOOTP.
- A problem was fixed that
caused a firmware installation from the HMC with the "do not auto
accept" option selected to fail.
- The field
replaceable unit (FRU) call-out list for clock card failures was
enhanced to reduce the number of parts replaced.
- A problem was fixed that
caused the bulk power controller (BPC) to erroneously log SRCs B181843C
and B181EF88, and a PWR dump to be generated.
System firmware changes that
affect certain systems
- HIPER/Non-Pervasive:
On systems running Active Memory Sharing (AMS) with a F/C 5803 or 5873
I/O drawer attached, a problem was fixed that caused the system to
crash with SRC B170E540 after a warm boot or platform dump IPL.
- On systems running a virtual I/O (VIO) partition, or using
a Shared Ethernet Adapter (SEA), a problem was fixed that caused a
severe performance degradation.
- On systems running IBM i partitions, a problem was fixed
that caused changing the processor weight on an IBM i partition to 255
to have no effect.
- On system using the utility capacity on demand (COD)
feature, a problem was fixed that prevented the hypervisor from
correctly crediting the time used when the sequence number of the
activation code reached certain values.
- On systems with an iSCSI
network, a problem was fixed that caused the system to hang when
booting from an iSCSI device in the system management services (SMS)
menus.
- On systems with an iSCSI
network, when booting a logical partition using that iSCSI network, a
problem was fixed that caused the iSCSI gateway parameter displayed on
the screen to be incorrect. It did not impact iSCSI boot
functionality.
- On systems using fibre channel
adapters, the firmware was enhanced by the addition of a new option in
the system management services (SMS) Mutliboot menu that facilitates
zoning of physical and virtual fibre channel adapters.
- On systems with
external I/O drawers, the firmware was enhanced such that SRCs 10001B02
and 1000911C place a call home.
- On systems with
external InfiniBand or PCI-E drawers or towers, a problem was fixed
that caused the system to crash with SRC B7000103 if the I/O hub
adapter crashed at the same time an external drawer or tower was being
initialized.
Concurrent hot add/repair
maintenance firmware fixes
- On partitions running Red Hat
Linux 6.1, a problem was fixed that caused a node evacuation operation
to fail.
- HIPER/Non-Pervasive:
On systems with a F/C 5803 or 5873 I/O drawer attached, a problem was
fixed that caused the system to crash with SRC B170E540 after a warm
boot or platform dump IPL.
- A problem was fixed
that caused the host Ethernet adapters (HEA) to be in a non-functional
state after a hot node add.
|
4.0
How to Determine Currently Installed Firmware Level
You can view the server's current firmware level on the Advanced System
Management Interface (ASMI) Welcome pane. It appears in the top right
corner.
Example: EH350_038.
5.0 Downloading
the
Firmware Package
Follow the instructions on Fix Central. You must read and agree to
the
license agreement to obtain the firmware packages.
Note: If your HMC or SDMC is not internet-connected you will need
to
download
the new firmware level to a CD-ROM or ftp server.
6.0 Installing the
Firmware
The method used to install new firmware will depend on the release
level
of firmware which is currently installed on your server. The release
level
can be determined by the prefix of the new firmware's filename.
Example: EHXXX_YYY_ZZZ
Where XXX = release level
- If the release level will stay the same (Example: Level
EH330_075_075
is
currently installed and you are attempting to install level
EH330_081_075)
this is considered an update.
- If the release level will change (Example: Level EH330_081_075 is
currently
installed and you are attempting to install level EH340_096_096) this
is
considered an upgrade.
Instructions for installing firmware updates and upgrades can be found
at http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/ipha1/updupdates.htm
IBM i Systems:
See "Server Firmware and HMC
Wizard":
http://www-912.ibm.com/s_dir/slkbase.nsf/recommendedfixes
7.0 Firmware History
The Firmware History can be reviewed at the following url: