Power9 System Firmware

Applies to:   9040-MR9

This document provides information about the installation of Licensed Machine or Licensed Internal Code, which is sometimes referred to generically as microcode or firmware.


Contents


1.0 Systems Affected

This package provides firmware for Power Systems E950 (9040-MR9) servers only.

The firmware level in this package is:

1.1 Minimum HMC Code Level

This section is intended to describe the "Minimum HMC Code Level" required by the System Firmware to complete the firmware installation process. When installing the System Firmware, the HMC level must be equal to or higher than the "Minimum HMC Code Level" before starting the system firmware update.  If the HMC managing the server targeted for the System Firmware update is running a code level lower than the "Minimum HMC Code Level" the firmware update will not proceed.

The Minimum HMC Code levels for this firmware for HMC x86,  ppc64 or ppc64le are listed below.

x86 -  This term is used to reference the legacy HMC that runs on x86/Intel/AMD  hardware for both the 7042 Machine Type appliances and the Virtual HMC that can run on the Intel hypervisors (KVM, VMWare, Xen).

ppc64 or ppc64le - describes the Linux code that is compiled to run on Power-based servers or LPARS (Logical Partitions)

For information concerning HMC releases and the latest PTFs,  go to the following URL to access Fix Central:
http://www-933.ibm.com/support/fixcentral/

For specific fix level information on key components of IBM Power Systems running the AIX, IBM i and Linux operating systems, we suggest using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home


NOTES:

                -You must be logged in as hscroot in order for the firmware installation to complete correctly.
                - Systems Director Management Console (SDMC) does not support this System Firmware level

2.0 Important Information

Downgrading firmware from any given release level to an earlier release level is not recommended.

If you feel that it is necessary to downgrade the firmware on your system to an earlier release level, please contact your next level of support.

2.1 IPv6 Support and Limitations

IPv6 (Internet Protocol version 6) is supported in the System Management Services (SMS) in this level of system firmware. There are several limitations that should be considered.

When configuring a network interface card (NIC) for remote IPL, only the most recently configured protocol (IPv4 or IPv6) is retained. For example, if the network interface card was previously configured with IPv4 information and is now being configured with IPv6 information, the IPv4 configuration information is discarded.

A single network interface card may only be chosen once for the boot device list. In other words, the interface cannot be configured for the IPv6 protocol and for the IPv4 protocol at the same time.

2.2 Concurrent Firmware Updates

Concurrent system firmware update is supported on HMC Managed Systems only.

2.3 Memory Considerations for Firmware Upgrades

Firmware Release Level upgrades and Service Pack updates may consume additional system memory.
Server firmware requires memory to support the logical partitions on the server. The amount of memory required by the server firmware varies according to several factors.
Factors influencing server firmware memory requirements include the following:
Generally, you can estimate the amount of memory required by server firmware to be approximately 8% of the system installed memory. The actual amount required will generally be less than 8%. However, there are some server models that require an absolute minimum amount of memory for server firmware, regardless of the previously mentioned considerations.

Additional information can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9hat/p9hat_lparmemory.htm


3.0 Firmware Information

Use the following examples as a reference to determine whether your installation will be concurrent or disruptive.

For systems that are not managed by an HMC, the installation of system firmware is always disruptive.

Note: The concurrent levels of system firmware may, on occasion, contain fixes that are known as Deferred and/or Partition-Deferred. Deferred fixes can be installed concurrently, but will not be activated until the next IPL. Partition-Deferred fixes can be installed concurrently, but will not be activated until a partition reactivate is performed. Deferred and/or Partition-Deferred fixes, if any, will be identified in the "Firmware Update Descriptions" table of this document. For these types of fixes (Deferred and/or Partition-Deferred) within a service pack, only the fixes in the service pack which cannot be concurrently activated are deferred.

Note: The file names and service pack levels used in the following examples are for clarification only, and are not necessarily levels that have been, or will be released.

System firmware file naming convention:

01VMxxx_yyy_zzz

NOTE: Values of service pack and last disruptive service pack level (yyy and zzz) are only unique within a release level (xxx). For example, 01VM900_040_040 and 01VM910_040_045 are different service packs.

An installation is disruptive if:

            Example: Currently installed release is 01VM900_040_040, new release is 01VM910_050_050.

            Example: VM910_040_040 is disruptive, no matter what level of VM910 is currently installed on the system.

            Example: Currently installed service pack is VM910_040_040 and new service pack is VM910_050_045.

An installation is concurrent if:

The release level (xxx) is the same, and
The service pack level (yyy) currently installed on the system is the same or higher than the last disruptive service pack level (zzz) of the service pack to be installed.

Example: Currently installed service pack is VM910_040_040, new service pack is VM910_041_040.

3.1 Firmware Information and Description

 
Filename Size Checksum md5sum
01VM920_040_040.rpm 118054232 35655
5383f38e5154e4065ca442998a2d0f35

Note: The Checksum can be found by running the AIX sum command against the rpm file (only the first 5 digits are listed).
ie: sum 01VM920_040_040.rpm

VM920
For Impact, Severity and other Firmware definitions, Please refer to the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs

The complete Firmware Fix History for this Release Level can be reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/VM-Firmware-Hist.html
VM920_040_040 / FW920.00

08/20/18
Impact:  New      Severity:  New

New Features and Functions
  • GA Level

4.0 How to Determine The Currently Installed Firmware Level

You can view the server's current firmware level on the Advanced System Management Interface (ASMI) Welcome pane. It appears in the top right corner. Example: VM920_123.


5.0 Downloading the Firmware Package

Follow the instructions on Fix Central. You must read and agree to the license agreement to obtain the firmware packages.

Note: If your HMC is not internet-connected you will need to download the new firmware level to a USB flash memory device or ftp server.


6.0 Installing the Firmware

The method used to install new firmware will depend on the release level of firmware which is currently installed on your server. The release level can be determined by the prefix of the new firmware's filename.

Example: VMxxx_yyy_zzz

Where xxx = release level

HMC Managed Systems:

Instructions for installing firmware updates and upgrades on systems managed by an HMC can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eh6/p9eh6_updates_sys.htm


NovaLink Managed Systems:

A NovaLink managed system does not have a HMC attached and is managed either by PowerVM Novalink or PowerVC using PowerVM Novalink.
Instructions for installing firmware updates and upgrades on systems managed by PowerVM NovaLink can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eig/p9eig_updating_firmware.htm


HMC and NovaLink Co-Managed Systems:

A co-managed system is managed by HMC and NovaLink, with one of the interfaces in the co-management master mode.
Instructions for installing firmware updates and upgrades on systems co-managed by an HMC and Novalink is the same as above for a HMC managed systems since the firmware update must be done by the HMC in the co-management master mode.  Before the firmware update is attempted, one must be sure that HMC is set in the master mode using the steps at the following IBM KnowledgeCenter link for NovaLink co-managed systems:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eig/p9eig_kickoff.htm

Then the firmware updates can proceed with the same steps as for the HMC managed systems:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eh6/p9eh6_updates_sys.htm


Systems not Managed by an HMC or NovaLink:

Power Systems:

Instructions for installing firmware on systems that are not managed by an HMC can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9ha5/fix_serv_firm_kick.htm


Systems running Ubuntu operating system:


If  Ubuntu will be used to update the system firmware, please follow these instructions to extract the installable binary and update/upgrade the firmware:

1) Download the .gz (tarball) from Fix Central to your Ubuntu system (ie, to /tmp/fwupdate).

2) Extract the .gz file to /tmp/ on the Ubuntu system:

Example:
    tar -xzf /tmp/fwupdate/01VM910_040_040.tar.gz -C /tmp/fwupdate

3) Use update_flash -v -f <extracted file name> to verify the package.

4) Update your firmware using update_flash:

/usr/sbin/update_flash  -f <extracted file name>

System will reboot during the firmware update. When the system reaches Ubuntu run-time state, you can then commit or reject the firmware update:
Commit: /usr/sbin/update_flash -c
Reject:   /usr/sbin/update_flash -r

IBM i Systems:

For information concerning IBM i Systems, go to the following URL to access Fix Central: 
http://www-933.ibm.com/support/fixcentral/

Choose "Select product", under Product Group specify "System i", under Product specify "IBM i", then Continue and specify the desired firmware PTF accordingly.

7.0 Firmware History

The complete Firmware Fix History (including HIPER descriptions)  for this Release level can be reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/VM-Firmware-Hist.html