Power9 System Firmware
Applies
to: 9008-22L; 9009-22A; 9009-41A; 9009-42A;
9223-22H; 9223-42H; 9009-41G; 9009-22G; 9009-42G; 9223-22S; 9223-42S
and 5105-22E .
This document provides information about the installation of
Licensed Machine or Licensed Internal Code, which is sometimes referred
to generically as microcode or firmware.
Contents
1.0
Systems Affected
This
package provides firmware for Power Systems L922 (9008-22L), Power
System S922 (9009-22A), Power System S914 (9009-41A), Power
System S924 (9009-42A), Power
System H922 (9223-22H) Power System H924 (9223-42H), Power
Systems S922 (9009-22G), Power
Systems S914 (9009-41G), Power Systems S924 (9009-42G), IBM Power
System H922 for SAP HANA (9223-22S), IBM Power System H924 for
SAP HANA (9223-42S), and IBM ESS (5105-22E) servers
only.
The firmware level in this package is:
1.1 Minimum HMC Code Level
This section is intended to describe the "Minimum HMC Code Level"
required by the System Firmware to complete the firmware installation
process. When installing the System Firmware, the HMC level must be
equal to or higher than the "Minimum HMC Code Level" before starting
the system firmware update. If the HMC managing the server
targeted for the System Firmware update is running a code level lower
than the "Minimum HMC Code Level" the firmware update will not proceed.
The
Minimum HMC Code levels for this firmware for HMC x86, ppc64
or ppc64le are listed below.
x86 - This term is used to reference the
legacy HMC
that runs on x86/Intel/AMD hardware for the Virtual HMC that can run on
the Intel
hypervisors (KVM, XEN, VMWare ESXi).
- The
Minimum HMC Code level for this firmware is: HMC V9R2M950
(PTF MH01869).
Note: The 7042-CR9 is the ONLY
Machine Type HMC appliances for x86 supported for the
Minimum HMC level.
- Although the Minimum HMC Code level for this firmware is listed
above, HMC V9R1M50.4 (PTF MH01881) or higher is recommended.
ppc64 or ppc64le - describes the Linux code that is compiled to
run on Power-based servers or LPARS (Logical Partitions)
- The
Minimum HMC Code level for this firmware is: HMC V9R2M950 (PTF
MH01870).
- Although the Minimum HMC Code level for this firmware is listed
above, HMC V9R1M50.4
(PTF
MH01882) or
higher is recommended.
The
Minimum HMC level supports the following HMC models:
x86 - KVM, XEN, VMWare ESXi (6.0/6.5)
ppc64le - 7063-CR1,vHMC on PowerVM (POWER8 and POWER9 systems
For
information
concerning HMC releases and the latest PTFs, go to the following
URL to access Fix Central:
http://www-933.ibm.com/support/fixcentral/
For specific fix level information on key components of IBM Power
Systems running the AIX, IBM i and Linux operating systems, we suggest
using the Fix Level Recommendation Tool (FLRT):
http://www14.software.ibm.com/webapp/set2/flrt/home
NOTES:
-You must be logged in as hscroot in order for the
firmware installation to complete correctly.
- Systems Director Management Console (SDMC) does not support this
System Firmware level
1.2 IBM i Minimum Levels
Reference the following URL for IBM i Support: Recommended fixes:
https://www-01.ibm.com/support/docview.wss?uid=nas8N1021194
2.0 Important Information
NovaLink
issue with remote start and inactive partition migration operations
There is a known issue with remote restart and inactive partition
migration operations initiated from NovaLink when the source system is
running this firmware level. Remote restart and inactive partition
migration functionality initiated from an HMC is not impacted by this
issue. When attempting these operations with PowerVC on a
NovaLink managed environment, a PVME01040100-0004 with Internal error
PVME01038003 may be encountered on the target system. This issue
is planned to be addressed in a future FW950.00 Service Pack.
Systems running with a previous firmware level should remain at that
level until a FW950 Service Pack is released which addresses the issue
with remote restart and inactive partition migration operations
initiated from Novalink. If you have systems shipped with FW950.00 and
require more immediate support for remote restart or inactive partition
migration operations initiated from NovaLink, please contact IBM
support.
Boot adapter microcode requirement
Update all adapters which are boot adapters, or which may be used as
boot adapters in the future, to the latest microcode from IBM Fix
Central. The latest microcode will ensure the adapters support
the new Firmware Secure Boot feature of Power Systems. This requirement
applies when updating system firmware from a level prior to FW940 to
levels FW940 and later.
The latest adapter microcode levels include signed boot driver code. If
a boot-capable PCI adapter is not installed with the latest level of
adapter microcode, the partition which owns the adapter will boot, but
error logs with SRCs BA5400A5 or BA5400A6 will be posted. Once
the adapter(s) are updated, the error logs will no longer be posted.
Downgrading firmware from any
given release level to an earlier release level is not recommended
Firmware downgrade warnings:
1) Adapter feature codes (#EC2R/#EC2S/#EC2T/#EC2U and
#EC3L/#EC3M and #EC66/EC67) when configured in SR-IOV shared mode in
FW930 or later, even if originally configured in shared mode
in a pre-FW930 release, may not function properly if the system is
downgraded to a pre-FW930 release. The adapter should be configured in
dedicated mode first (i.e. take the adapter out of SR-IOV shared mode)
before downgrading to a pre-FW930 release.
2) If partitions have been run in POWER9 compatibility mode in FW940, a
downgrade to an earlier release (pre-FW940) may cause a problem with
the partitions starting. To prevent this problem, the "server
firmware" settings must be reset by rebooting partitions in
"Power9_base" before doing the downgrade.
If you feel that it is
necessary to downgrade the firmware on your system to an earlier
release level, please contact your next level of support.
Upgrade from FW941.00 to FW950
will change the QPRCFEAT QMODEL code for the 9009-22G, 9009-41G, and
9009-42G models.
If updating from FW941.00 to FW950 for IBM i, there is a
fix for incorrect QPRCFEAT QMODEL values for the 9009-xxG models.
If 3rd party software licenses were installed based on the old
incorrect QPRCFEAT QMODEL value, new licenses will be needed to work
with the updated value: The QPRCFEAT QMODEL IBM System Value was
showing the 9009-xxG models as 9009-xxA models. For example, the
9009-22G reported as "EP11" instead of "EP51". This mismatch can
prevent 3rd party software licenses from working.
2.1 IPv6 Support and
Limitations
IPv6 (Internet Protocol version 6)
is supported in the System Management Services (SMS) in this level of
system firmware. There are several limitations that should be
considered.
When configuring a network interface
card (NIC) for remote IPL, only the most recently configured protocol
(IPv4 or IPv6) is retained. For example, if the network interface card
was previously configured with IPv4 information and is now being
configured with IPv6 information, the IPv4 configuration information is
discarded.
A single network interface card
may only be chosen once for the boot device list. In other words, the
interface cannot be configured for the IPv6 protocol and for the IPv4
protocol at the same time.
2.2 Concurrent
Firmware Updates
Concurrent system firmware update is supported on HMC Managed Systems
only.
Ensure that there are no RMC connections issues for any system
partitions prior to applying the firmware update. If there is a
RMC connection failure to a partition during the firmware update, the
RMC connection will need to be restored and additional recovery actions
for that partition will be required to complete partition firmware
updates.
2.3 Memory Considerations for
Firmware Upgrades
Firmware Release Level upgrades and
Service Pack updates may consume additional system memory.
Server firmware requires memory to
support the logical partitions on the server. The amount of memory
required by the server firmware varies according to several factors.
Factors influencing server firmware
memory requirements include the following:
- Number of logical partitions
- Partition environments of the logical
partitions
- Number of physical and virtual I/O devices
used by the logical partitions
- Maximum memory values given to the logical
partitions
Generally, you can estimate the
amount of memory required by server firmware to be approximately 8% of
the system installed memory. The actual amount required will generally
be less than 8%. However, there are some server models that require an
absolute minimum amount of memory for server firmware, regardless of
the previously mentioned considerations.
Additional information can be found
at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9hat/p9hat_lparmemory.htm
2.4 SBE Updates
Power 9 servers
contain SBEs (Self Boot Engines) and are used to boot the system.
SBE is internal to each of the Power 9 chips and used to "self boot"
the chip. The SBE image is persistent and is only reloaded if
there is a system firmware update that contains a SBE change. If
there is a SBE change and system firmware update is concurrent, then
the SBE update is delayed to the next IPL of the CEC which will cause
an additional 3-5 minutes per processor chip in the system to be added
on to the IPL. If there is a SBE change and the system firmware
update is disruptive, then SBE update will cause an additional 3-5
minutes per processor chip in the system to be added on to the
IPL. During the SBE update process, the HMC or op-panel will
display service processor code C1C3C213 for each of the SBEs being
updated. This is a normal progress code and system boot should be
not be terminated by the user. Additional time estimate can be between
6-10 minutes.
The SBE image is updated with this
service pack.
2.5 NVDIMM Updates
Power 9 ESS 5010-22E servers contain NVDIMMs that may be updated with a
service pack. Updating NVDIMM firmware takes approximately 8 minutes
per NVDIMM on ESS I/O servers 5105-22E. If an NVDIMM firmware update is
required, then this would be incurred only on the initial system boot
when updating system firmware or replacing an NVDIMM. There are 4
NVDIMMs per server, so up to an additional 32 minutes might be needed
to complete the system boot in these cases.
The NVDIMM firmware is updated with
this service pack.
3.0 Firmware Information
Use the following examples as a reference to determine whether your
installation will be concurrent or disruptive.
For systems that are not managed by an HMC, the installation of
system firmware is always disruptive.
Note: The concurrent levels
of system firmware may, on occasion, contain fixes that are known as
Deferred and/or Partition-Deferred. Deferred fixes can be installed
concurrently, but will not be activated until the next IPL.
Partition-Deferred fixes can be installed concurrently, but will not be
activated until a partition reactivate is performed. Deferred and/or
Partition-Deferred fixes, if any, will be identified in the "Firmware
Update Descriptions" table of this document. For these types of fixes (Deferred and/or
Partition-Deferred) within a service pack, only the fixes in the
service pack which cannot be concurrently activated are deferred.
Note: The file names and service pack levels used in the
following examples are for clarification only, and are not necessarily
levels that have been, or will be released.
System firmware file naming convention:
01VLxxx_yyy_zzz
- xxx is the release level
- yyy is the service pack level
- zzz is the last disruptive service pack level
NOTE: Values of service pack and last disruptive service pack
level (yyy and zzz) are only unique within a release level (xxx). For
example, 01VL900_040_040 and 01VL910_040_045 are different
service packs.
An installation is disruptive if:
- The release levels (xxx) are
different.
Example:
Currently installed release is 01VL900_040_040,
new release is 01VL910_050_050.
- The service pack level (yyy) and the last disruptive
service pack level (zzz) are the same.
Example: VL910_040_040
is disruptive, no matter what level of VL910 is currently installed on
the system.
- The service pack level (yyy) currently installed on the
system is lower than the last disruptive service pack level (zzz) of
the service pack to be installed.
Example:
Currently installed service pack is VL910_040_040 and new service pack
is VL910_050_045.
An installation is concurrent if:
The release level (xxx) is the same, and
The service pack level (yyy) currently installed on the system
is the same or higher than the last disruptive service pack level (zzz)
of the service pack to be installed.
Example: Currently installed service pack is VL910_040_040, new
service pack is VL910_041_040.
3.1 Firmware
Information and Description
Filename |
Size |
Checksum |
md5sum |
01VL950_072_045.rpm |
168933640
|
49027
|
18bf575c1b79601d0ae92a5dc673f96e
|
Note: The Checksum can be found by running the AIX sum command against
the rpm file (only the first 5 digits are listed).
ie: sum 01VL950_072_045.rpm
VL950
For Impact, Severity and other Firmware definitions, Please refer to
the below 'Glossary of firmware terms' url:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html#termdefs
The
complete Firmware Fix History for this Release Level can be reviewed at
the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/VL-Firmware-Hist.html
|
VL950_072_045 / FW950.10
04/28/21 |
Impact: Data
Severity: HIPER
New Features and Functions
- Support added to Redfish to provide a command to set the
ASMI user passwords using a new AccountService schema. Using this
service, the ASMI admin, HMC, and general user passwords can be changed.
- PowerVM support for the Platform KeyStore (PKS) for
partitions has removed the FW950.00 restriction where the total amount
of PKS for the system that could be configured was limited to 1 MB
across all the partitions. This restriction has been removed for
FW950.10.
This feature does not pertain to model ESS 5105-22E.
- Support was added for a 12-core 2.3G/2.7G 190W/225W
processor module with feature codes #EP5W and #EP5X. This
processor has CCIN 5C3D and runs in DD2.3 mode.
This feature pertains only to IBM Power System models S922(9009-22G)
and H922(9223-22S).
- Support was added for Samsung DIMMs with part number
01GY853. If these DIMMs are installed in a system with older
firmware than FW950.10, the DIMMs will fail and be guarded with SRC
BC8A090F logged with HwpReturnCode "
RC_CEN_MBVPD_TERM_DATA_UNSUPPORTED_VPD_ENCODE".
- Support was added for a new service processor command that
can be used to 'lock' the power management mode, such that the mode can
not be changed except by doing a factory reset.
- Support for new mainstream 931 GB, 1.86 TB, 3.72 TB, and
7.44 TB capacity SSDs. A 2.5-inch serial-attached SCSI (SAS) SSD
is mounted on an SFF-3 carrier or tray for a POWER9 system unit or
mounted on an SFF-2 for placement in an expansion drawer, such as the
EXP24SX drawer, when attached to a POWER9 server. The drive is
formatted to use 4224-byte (4k) sectors and does not support the 4k
JBOD 4096-byte sector. Firmware level FW950.10 or later is
required for these drives. The following are the feature codes
and CCINs for the new drives:
#ESKJ/#ESKK with CCIN 5B2B/5B29 – 931 GB Mainstream SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESKL/#ESKM with CCIN 5B2B/5B29 - 931GB Mainstream SAS 4k SFF-3/SFF-2
SSD for IBM i
#ESKN/#ESKP with CCIN 5B20/5B21- 1.86TB Mainstream SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESKQ/#ESKR with CCIN 5B20/5B21- 1.86TB Mainstream SAS 4k SFF-3/SFF-2
SSD for IBM i
#ESKS/#ESKT with CCIN 5B2C/5B2D - 3.72TB Mainstream SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESKU/#ESKV with CCIN 5B2C/5B2D - 3.72TB Mainstream SAS 4k SFF-3/SFF-2
SSD for IBM i
#ESKW/#ESKX with CCIN 5B2E/5B2F- 7.44TB Mainstream SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESKY/#ESKZ with CCIN 5B2E/5B2F -7.44TB Mainstream SAS 4k SFF-3/SFF-2
SSD for IBM i
- Support for new enterprise SSDs refresh the previously
available 387 GB, 775 GB, and 1550 GB capacity points for POWER9
servers. These are 400 GB, 800 GB, and 1600 GB SSDs that are always
formatted either to 4224 (4k) byte sectors or to 528 (5xx) byte sectors
for additional protection, resulting in 387 GB, 775 GB, and 1550 GB
capacities. The 4096-byte sector, the 512-byte sector, and JBOD are not
supported. Firmware level FW950.10 or later is required for these
drives. The following are the feature codes and CCINs for the new
drives:
#ESK0/#ESK1 with CCIN 5B19/ 5B16 - 387GB Enterprise SAS 5xx
SFF-3/SFF-2 SSD for AIX/Linux
#ESK2/#ESK3 with CCIN 5B1A/5B17 - 775GB Enterprise SAS 5xx SFF-3/SFF-2
SSD for AIX/Linux
#ESK6/#ESK8 with CCIN 5B13/5B10.- 387GB Enterprise SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESK7/#ESK9 with CCIN 5B13/5B10- 387GB Enterprise SAS 4k SFF-3/SFF-2
SSD for IBM i
#ESKA/#ESKC with CCIN 5B14/5B11- 775GB Enterprise SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESKB/#ESKD with CCIN 5B14/5B11- 775GB Enterprise SAS 4k SFF-3/SFF-2
SSD for IBM i
#ESKE/#ESKG with CCIN 5B15/5B12- 1.55TB Enterprise SAS 4k SFF-3/SFF-2
SSD for AIX/Linux
#ESKF/#ESKH with CCIN 5B15/5B12- 1.55TB Enterprise SAS 4k SFF-3/SFF-2
SSD for IBM i
- Support for new PCIe 4.0 x8 dual-port 32 Gb optical Fibre
Channel (FC) short form adapter based on the Marvell QLE2772 PCIe host
bus adapter (6.6 inches x 2.731 inches). The adapter provides two ports
of 32 Gb FC capability using SR optics. Each port can provide up to
6,400 MBps bandwidth. This adapter has feature codes #EN1J/#EN1K with
CCIN 579C. Firmware level FW950.10 or later is required for this
adapter.
- Support for new PCIe 3.0 16 Gb quad-port optical Fibre
Channel (FC)l x8 short form adapter based on the Marvell QLE2694L PCIe
host bus adapter (6.6 inches x 2.371 inches). The adapter provides four
ports of 16 Gb FC capability using SR optics. Each port can provide up
to 3,200 MBps bandwidth. This adapter has feature codes #EN1E/#EN1F
with CCIN 579A. Firmware level FW950.10 or later is required for this
adapter.
- Support for Enterprise 800 GB PCIe4 NVMe SFF U.2 15mm SSD
for IBM i. The SSD can be used in any U.2 15mm NVMe slot in the system.
This drive has feature code #ES1K and CCIN 5947. Firmware level
FW950.10 or later is required for this drive.
- Added support in
ASMI for a new panel to do Self -Boot Engine (SBE) SEEPROM
validation. This validation can only be run at the service
processor standby state.
If the validation
detects a problem, IBM recommends the system not be used and that IBM
service be called.
System firmware changes that
affect all systems
- HIPER/Pervasive: A
problem was fixed for a system IPL failure when DIMMs (RDIMMs or
NVDIMMs) have mixed configurations with dual populated memory channels
and single populated memory channels. This problem occurs If
there are dually populated memory channels that precede a single DIMM
memory channel for a processor. This causes the IPL to fail with
B150BA40 and BC8A090F logged with HwpReturnCode
"RC_MSS_CALC_POWER_CURVE_NEGATIVE_OR_ZERO_SLOPE " and HWP Error
description "Power curve slope equals 0 or is negative". A
workaround for this problem is to reconfigure the memory to have the
single DIMM memory channels be in front of memory channels that have
both DIMM slots occupied.
- A problem was fixed for certain SR-IOV adapters that have a
rare, intermittent error with B400FF02 and B400FF04 logged, causing a
reboot of the VF. The error is handled and recovered without any
user intervention needed. The SR-IOV adapters affected have the
following Feature Codes and CCINs: #EC2R/#EC2S with CCIN 58FA;
#EC2T/#EC2U with CCIN 58FB; #EC3L/#EC3M with CCIN 2CE; and #EC66/#EC67
with CCIN 2CF3.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for initiating a Remote Restart from a
PowerVC/NovaLink source system to a remote target. This happens
whenever the source system is running FW950.00. The error would look
like this from PowerVC (system name, release level would be specific to
the environment):
"Virtual machine RR-5 could not be remote restarted to
Ubu_AX_9.114.255.10. Error message: PowerVM API failed to complete for
instance=RR-5-71f5c2cf-0000004e.HTTP error 500 for method PUT on path
/rest/api/uom/ManagedSystem/598c1be4-cb4c-3957-917d-327b764d8ac1/LogicalPartition:
Internal Server Error -- [PVME01040100-0004] Internal error
PVME01038003 occurred while trying to perform this command.".
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for a B1502616 SRC logged after a
system is powered off. This rare error, "A critical error
occurred on the thermal/power management device (TPMD); it is being
disabled. " is not a real problem but occurred because the Power
Management (PM) complex was being reset during the power off. No
recovery is needed as the next IPL of the system is successful.
- A problem was fixed for the error handling of a system with
an unsupported memory configuration that exceeds available memory
power. Without the fix, the IPL of the system is attempted and fails
with a segmentation fault with SRCs B1818611 and B181460B logged that
do not call out the incorrect DIMMs.
- A problem was fixed for an error in the HMC GUI (Error
launching task) when clicking on "Hardware Virtualized IO". This error
is infrequent and is triggered by an optical cable to a PCIe3 #EMX0
expansion drawer that is failed or unplugged. With the fix, the
HMC can show the working I/O adapters.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for performance degradation of a
partition due to task dispatching delays. This may happen when a
processor chip has all of its shared processors removed and converted
to dedicated processors. This could be driven by DLPAR remove of
processors or Dynamic Platform Optimization (DPO).
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for an unrecoverable UE SRC B181BE12
being logged if a service processor message acknowledgment is sent to a
Hostboot instance that has already shutdown. This is a harmless
error log and it should have been marked as an informational log.
- A problem was fixed for Time of Day (TOD) being lost for
the real-time clock (RTC) with an SRC B15A3303 logged when the service
processor boots or resets. This is a very rare problem that
involves a timing problem in the service processor kernel. If the
server is running when the error occurs, there will be an SRC B15A3303
logged, and the time of day on the service processor will be incorrect
for up to six hours until the hypervisor synchronizes its (valid) time
with the service processor. If the server is not running when the
error occurs, there will be an SRC B15A3303 logged, and If the server
is subsequently IPLed without setting the date and time in ASMI to fix
it, the IPL will abort with an SRC B7881201 which indicates to the
system operator that the date and time are invalid.
- A problem was fixed for the Systems Management Services (
SMS) menu "Device IO Information" option being incorrect when
displaying the capacity for an NVMe or Fibre Channel (FC) NVMe
disk. This problem occurs every time the data is displayed.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for intermittent failures for a reset
of a Virtual Function (VF) for SR-IOV adapters during Enhanced Error
Handling (EEH) error recovery. This is triggered by EEH events at a VF
level only, not at the adapter level. The error recovery fails if a
data packet is received by the VF while the EEH recovery is in
progress. A VF that has failed can be recovered by a partition reboot
or a DLPAR remove and add of the VF.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for a logical partition activation
error that can occur when trying to activate a partition when the
adapter hardware for an SR-IOV logical port has been physically removed
or is unavailable due to a hardware issue. This message is reported on
the HMC for the activation failure: "Error: HSCL12B5 The
operation to remove SR-IOV logical port <number> failed because
of the following error: HSCL1552 The firmware operation failed with
extended error" where the logical port number will vary. This is
an infrequent problem that is only an issue if the adapter hardware has
been removed or another problem makes it unavailable. The
workaround for this problem is to physically add the hardware back in
or correct the hardware issue. If that cannot be done, create an
alternate profile for the logical partition without the SR-IOV logical
port and use that until the hardware issue is resolved.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for incomplete periodic data gathered
by IBM Service for #EMXO PCIe expansion drawer predictive error
analysis. The service data is missing the PLX (PCIe switch) data
that is needed for the debug of certain errors.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for a partition hang in shutdown with
SRC B200F00F logged. The trigger for the problem is an
asynchronous NX accelerator job (such as gzip or NX842 compression) in
the partition that fails to clean up successfully. This is
intermittent and does not cause a problem until a shutdown of the
partition is attempted. The hung partition can be recovered by
performing an LPAR dump on the hung partition. When the dump has
been completed, the partition will be properly shut down and can then
be restarted without any errors.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for a rare failure for an SPCN I2C
command sent to a PCIe I/O expansion drawer that can occur when service
data is manually collected with hypervisor macros "xmsvc -dumpCCData
and xmsvc -logCCErrBuffer". If the hypervisor macro "xmsvc
"is run to gather service data and a CMC Alert occurs at the same time
that requires an SPCN command to clear the alert, then the I2C commands
may be improperly serialized, resulting in an SPCN I2C command
failure. To prevent this problem, avoid using xmsvc
-dumpCCData and xmsvc -logCCErrBuffer to collect service data until
this fix is applied.
This problem does not pertain to model ESS 5105-22E.
- The following problems were fixed for certain SR-IOV
adapters:
1) An error was fixed that occurs during a VNIC failover where the VNIC
backing device has a physical port down or read port errors with an SRC
B400FF02 logged.
2) A problem was fixed for adding a new logical port that has a PVID
assigned that is causing traffic on that VLAN to be dropped by other
interfaces on the same physical port which uses OS VLAN tagging for
that same VLAN ID. This problem occurs each time a logical port
with a non-zero PVID that is the same as an existing VLAN is
dynamically added to a partition or is activated as part of a partition
activation, the traffic flow stops for other partitions with OS
configured VLAN devices with the same VLAN ID. This problem can
be recovered by configuring an IP address on the logical port with the
non-zero PVID and initiating traffic flow on this logical port.
This problem can be avoided by not configuring logical ports with a
PVID if other logical ports on the same physical port are configured
with OS VLAN devices.
This fix updates the adapter firmware to 11.4.415.37 for the following
Feature Codes and CCINs: #EN15/#EN16 with CCIN 2CE3, #EN17/#EN18
with CCIN 2CE4, #EN0H/#EN0J with CCIN 2B93, #EN0M/#EN0N with CCIN 2CC0,
#EN0K/#EN0L with CCIN 2CC1, #EL56/#EL38 with CCIN 2B93, and #EL57/#EL3C
with CCIN 2CC1.
The SR-IOV adapter firmware level update for the shared-mode adapters
happens under user control to prevent unexpected temporary outages on
the adapters. A system reboot will update all SR-IOV shared-mode
adapters with the new firmware level. In addition, when an
adapter is first set to SR-IOV shared mode, the adapter firmware is
updated to the latest level available with the system firmware (and it
is also updated automatically during maintenance operations, such as
when the adapter is stopped or replaced). And lastly, selective
manual updates of the SR-IOV adapters can be performed using the
Hardware Management Console (HMC). To selectively update the
adapter firmware, follow the steps given at the IBM Knowledge Center
for using HMC to make the updates: https://www.ibm.com/support/knowledgecenter/en/POWER9/p9efd/p9efd_updating_sriov_firmware.htm.
Note: Adapters that are capable of running in SR-IOV mode, but are
currently running in dedicated mode and assigned to a partition, can be
updated concurrently either by the OS that owns the adapter or the
managing HMC (if OS is AIX or VIOS and RMC is running).
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for certain PCIe adapters and NVMe U.2
devices to lower fan speeds where additional cooling is not needed. The
following feature codes are affected in the 9009-22G, 9009-41G,
9009-42G, and 5105-22E servers: #EC5J with CCIN 59B4; #EC5X
with CCIN 59B7; and #ES1E/#ES1F with CCIN 59B8.
- A problem was fixed for a system hang or terminate with SRC
B700F105 logged during a Dynamic Platform Optimization (DPO) that is
running with a partition in a failed state but that is not shut
down. If DPO attempts to relocate a dedicated processor from the
failed partition, the problem may occur. This problem can be
avoided by doing a shutdown of any failed partitions before initiating
DPO.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for a system crash with HMC message
HSCL025D and SRC B700F103 logged on a Live Partition Mobility (LPM)
inactive migration attempt that fails. The trigger for this problem is
inactive migration that fails a compatibility check between the source
and target systems.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for certain SR-IOV adapters not being
able to create the maximum number of VLANs that are supported for a
physical port. There were insufficient memory pages allocated for the
physical functions for this adapter type. The SR-IOV adapters affected
have the following Feature Codes and CCINs: #EC66/#EC67 with CCIN
2CF3.
This problem does not pertain to model ESS 5105-22E.
- A problem was fixed for certain SR-IOV adapters that can
have B400FF02 SRCs logged with LPA dumps during a vNIC remove
operation. The adapters can have issues with a deadlock in
managing memory pages. In most cases, the operations should
recover and complete. This fix updates the adapter firmware to
XX.29.2003 for the following Feature Codes and CCINs: #EC2R/EC2S with
CCIN 58FA; #EC2T/EC2U with CCIN 58FB; #EC3L/EC3M with CCIN 2CE; and
#EC66/EC67 with CCIN 2CF3.
The SR-IOV adapter firmware level update for the shared-mode adapters
happens under user control to prevent unexpected temporary outages on
the adapters. A system reboot will update all SR-IOV shared-mode
adapters with the new firmware level. In addition, when an
adapter is first set to SR-IOV shared mode, the adapter firmware is
updated to the latest level available with the system firmware (and it
is also updated automatically during maintenance operations, such as
when the adapter is stopped or replaced). And lastly, selective
manual updates of the SR-IOV adapters can be performed using the
Hardware Management Console (HMC). To selectively update the
adapter firmware, follow the steps given at the IBM Knowledge Center
for using HMC to make the updates: https://www.ibm.com/support/knowledgecenter/en/POWER9/p9efd/p9efd_updating_sriov_firmware.htm.
Note: Adapters that are capable of running in SR-IOV mode, but are
currently running in dedicated mode and assigned to a partition, can be
updated concurrently either by the OS that owns the adapter or the
managing HMC (if OS is AIX or VIOS and RMC is running).
This problem does not pertain to model ESS 5105-22E.
System firmware changes that
affect all systems
- HIPER/Pervasive: A
problem was fixed for a very small timing window which may prevent the
saving of volatile write cache in the NVDIMM in the event of a
surprised/unscheduled power down of the system or power down with the
SBE in an error state. This may result in data loss for the
storage system.
The update of the NVDIMM firmware takes approximately 8 minutes per
NVDIMM. This is incurred only on the initial system boot after updating
system firmware or replacing an NVDIMM. There are 4 NVDIMMs per server
so up to an additional 32 minutes could be needed to complete the
system boot in these cases. Please refer to section 2.5 of the readme
for more information on updates to NVDIMMs.
This problem pertains to model ESS 5105-22E only.
- HIPER/Pervasive: On
systems with OPAL firmware, a problem was fixed for intermittent
B150DAA0 and/or B181DA93 errors during power off. On the
subsequent IPL, the system will terminate with an SRC BC23352C pointing
to an NVDIMM. An NVDIMM factory reset is then required to clear
that condition. Because of this error, the SBE was unable to save
NVDIMM data, resulting in a loss of data.
This problem pertains to model ESS 5105-22E only.
- HIPER/Pervasive: On
systems with OPAL firmware, a problem was fixed for a processor core
checkstop with SRC BC70E540 logged with Signature Description "
ex(n0p1c4) (NCUFIR[11]) NCU no response to snooped TLBIE". This
problem is intermittent and random but occurs with relatively high
frequency for certain workloads. The trigger for the failure is
one core of a fused core pair going into a stopped state while the
other core of the pair continues running.
This problem pertains to model ESS 5105-22E only.
- On systems with OPAL firmware, a problem was fixed for
sporadic error messages in the OPAL log for xscom read/write
calls. These calls are handled internally and are not in the
error log, so these informational messages should not be printed in the
OPAL log.
This problem pertains to model ESS 5105-22E only.
- On systems with OPAL firmware, a problem was fixed for a
Linux OS hang on reboot that can occur if there is an error during fast
reboot. With the fix, if a fast reboot cannot be supported, a
normal reboot is done instead.
This problem pertains to model ESS 5105-22E only.
- A problem was fixed for a fast automatic recovery for an
NVDIMM slot 0 error with SRC BC23550 logged. This is a recovery fix
that changes recovery from many minutes (approximately 10 minutes per
NVDIMM) with a re-IPL going through NVDIMM firmware reload, to less
than 10 seconds with no re-lPL required.
This problem pertains to model ESS 5105-22E only.
- A problem was fixed for a missing SRC and callout for when
an NVDIMM does not have enough energy is save the NVDIMM image on a
loss of power for the system. Although the NVDIMM data loss is
recognized by the storage system, the lack of an SRC makes it difficult
to isolate the failing hardware for repair or replacement.
This problem pertains to model ESS 5105-22E only.
- On systems with an IBM i partition, a problem was fixed for
physical I/O property data not being able to be collected for an
inactive partition booted in "IOR" mode with SRC B200A101 logged. This
can happen when making a system plan (sysplan) for an IBM i partition
using the HMC and the IBM i partition is inactive. The sysplan
data collection for the active IBM i partitions is successful.
This problem does not pertain to model ESS 5105-22E.
|
VL950_045_045 / FW950.00
11/23/20 |
Impact:
New Severity: New
GA Level with key features
included listed below
- All features and fixes from the FW930.30, FW940.20, and
FW941.03 service packs (and below) are included in this release.
New Features and Functions
- Host firmware support for anti-rollback protection.
This feature implements firmware anti-rollback protection as described
in NIST SP 800-147B "BIOS Protection Guidelines for Servers".
Firmware is signed with a "secure version". Support added
for a new menu in ASMI called "Host firmware security policy" to update
this secure version level at the processor hardware. Using this
menu, the system administrator can enable the "Host firmware secure
version lock-in" policy, which will cause the host firmware to update
the "minimum secure version" to match the currently running firmware.
Use the "Firmware Update Policy" menu in ASMI to show the current
"minimum secure version" in the processor hardware along with the
"Minimum code level supported" information. The secure boot
verification process will block installing any firmware secure version
that is less than the "minimum secure version" maintained in the
processor hardware.
Prior to enabling the "lock-in" policy, it is recommended to accept the
current firmware level.
WARNING: Once lock-in is enabled and the system is booted, the "minimum
secure version" is updated and there is no way to roll it back to allow
installing firmware releases with a lesser secure version.
Note: If upgrading from FW930.30 or FW940.20, this feature is
already applied.
- Support added for IBM Power System H922 for SAP HANA
((9223-22S) and IBM Power System H924 for SAP HANA ((9223-22S).
These models have integrated PCIe Gen4 switches.
- OPAL is supported with skiboot level v6.6.4 and petitboot
level v1.12. This pertains to model ESS 5105-22E only.
- This server firmware level includes the SR-IOV adapter
firmware level 11.4.415.33 for the following Feature Codes and CCINs:
#EN15/EN16 with CCIN 2CE3, #EN17/EN18 with CCIN 2CE4, #EN0H/EN0J with
CCIN 2B93, #EN0M/EN0N with CCIN 2CC0, #EN0K/EN0L with CCIN 2CC1,
#EL56/EL38 with CCIN 2B93, and #EL57/EL3C with CCIN 2CC1.
- This server firmware includes the SR-IOV adapter firmware
level 1x.25.6100 for the following Feature Codes and CCINs: #EC2R/EC2S
with CCIN 58FA; #EC2T/EC2U with CCIN 58FB; #EC3L/EC3M with CCIN 2CEC;
and #EC66/EC67 with CCIN 2CF3.
- Support added for a 110V/900W power supply on the 9009-22G
model.
- Support added for IBM i 7.1 (Tech Refresh 11 + PTFs) for
restricted I/O only on the S922 (9009-22A) model.
- Support for PCIe4 x8 1.6/3.2/6.4 TB NVMe Adapters that are
Peripheral Component Interconnect Express (PCIe) Generation 4 (Gen4) x8
adapters with the following feature codes and CCINs:
#EC7A/#EC7B with CCIN 594A ; #EC7C/#EC7D with CCIN 594B; and
#EC7E/#EC7F with CCIN 594C for AIX/Linux.
#EC7J/#EC7K with CCIN 594A ; #EC7L/#EC7M with CCIN 594B; and
#EC7N/#EC7P with CCIN 594C for IBM i.
- PowerVM boot support for AIX for NVMe over Fabrics (NVMf)
for 32Gb Fibre Channel. Natively attached adapters are supported
with the following feature codes and CCINs: #EN1A/#EN1B with CCIN 578F.
- Support added for a PCIe2 2-Port USB 3.0 adapter with the
following feature codes and CCIN: #EC6J/#EC6K with CCIN 590F.
- Support added for dedicated processor partitions in IBM
Power Enterprise Pools (PEP) 2.0. Previously, systems added to
PEP 2.0 needed to have all partitions as shared processor partitions.
- Support added for SR-IOV Hybrid Network Virtualization
(HNV) for Linux. This capability allows a Linux partition
to take advantage of the efficiency and performance benefits of SR-IOV
logical ports and participate in mobility operations such as active and
inactive Live Partition Mobility (LPM) and Simplified Remote Restart
(SRR). HNV is enabled by selecting a new Migratable option when
an SR-IOV logical port is configured. The Migratable option is used to
create a backup virtual device. The backup virtual device must be
a Virtual Ethernet adapter (virtual Network Interface Controller (vNIC)
adapter not supported as a backup device). In addition to this
firmware, HNV support in a production environment requires HMC
9.1.941.0 or later, RHEL 8., SLES 15, and VIOS 3.1.1.20 or later.
- Enhanced Dynamic DMA Window (DDW) for I/O adapter
slots to enable the OS to use 64KB TCEs. The OS supported
is Linux RHEL 8.3 LE.
- PowerVM support for the Platform KeyStore (PKS) for
partitions. PowerVM has added new h-call interfaces allowing the
partition to interact with the Platform KeyStore that is maintained by
PowerVM. This keystore can be used by the partition to store
items requiring confidentiality or integrity like encryption keys or
certificates.
Note: The total amount of PKS for the system is limited to 1 MB
across all the partitions for FW950.00.
- Support for 64 GB 16Gbit DDR4 system memory running at 2666
Mhz with feature code #EM7B and part number 78P6815.
- Support for 128 GB 16Gbit DDR4 system memory running at
2666 Mhz with feature code #EM7C and part number 78P6925.
System firmware changes that
affect all systems
- HIPER/Pervasive:
A problem was fixed to be able to detect a failed PFET sensing circuit
in a core at runtime, and prevent a system fail with an incomplete
state when a core fails to wake up. The failed core is detected
on the subsequent IPL. With the fix. a core is called out with
the PFET failure with SRC BC13090F and hardware description "CME
detected malfunctioning of PFET headers." to isolate the error better
with a correct callout.
- A problem was fixed in ASMI for the Update Access Key (UAK)
displaying as "0000-00-00" on the OPAL systems. With the fix, the
UAK displays as "NA" since it is not used for this type of system
during the firmware update. This problem pertains only to the
5105-22E model.
- A problem was fixed for a VIOS, AIX, or Linux partition
hang during an activation at SRC CA000040. This will occur on a
system that has been running more than 814 days when the boot of the
partition is attempted if the partitions are in POWER9_base or POWER9
processor compatibility mode.
A workaround to this problem is to re-IPL the system or to change the
failing partition to POWER8 compatibility mode.
Note: If upgrading from FW930.30, this fix is already applied.
- A problem was fixed for certain PCIe adapters and NVMe U.2
devices. The following feature codes are affected and the presence of
these features in the 9009-41G and 9009-41A servers can result in
higher fan speeds and therefore higher acoustic levels after upgrading
the firmware (the other models are also affected but to a lesser
extent). Refer to the acoustic levels published in the IBM
Knowledge Center currently located at ===> https://www.ibm.com/support/knowledgecenter/9009-41A/p9had/p9had_90x.htm:
#EC5J witn CCIN 59B4; #EC5K with CCIN 59B5; #EC5L with CCIN 59B6;
#EC5X with CCIN 59B7; #EC7A/#EC7B with CCIN 594A; #EC7C/#EC7D
with CCIN 594B; #EC7E/#EC7F with CCIN 594C; #EC7J/#EC7K with
CCIN 594A; #EC7L/#EC7M with CCIN 594B; #EC7N/#EC7P with
CCIN 594C; #ES1E/#ES1F with CCIN 59B8; #ES1G/#ES1H with CCIN
59B9; #EC5V/#EC5W with CCIN 59BA; #EC5G/#EC5B and #EC6U/#EC6V
with CCIN 58FC; #EC5W/#EC5D and #EC6W/#EC6X with CCIN 58FD; and
#EC5G/#EC5B and #EC6Y/#EC6Z with CCIN 58FE.
Note: A version of this fix in earlier service pack FW941.03 did
not add cooling for the 9009-22A and 9009-22G models for the following
adapters: #EC5G/#EC5B and #EC6U/#EC6V with CCIN 58FC; #EC5W/#EC5D
and #EC6W/#EC6X with CCIN 58FD; and #EC5G/#EC5B and #EC6Y/#EC6Z with
CCIN 58FE.
- A problem was
fixed for a security vulnerability for the Self Boot Engine (SBE). The
SBE can be compromised from the service processor to allow injection of
malicious code. An attacker that gains root access to the service
processor could compromise the integrity of the host firmware and
bypass the host firmware signature verification process. This
compromised state can not be detected through TPM attestation.
This is Common Vulnerabilities and Exposures issue number
CVE-2021-20487.
System firmware changes that
affect all systems
- On systems with an IBM i partition, a problem was fixed for
the QPRCFEAT QMODEL IBM System Value showing the 9009-xxG models as
9009-xxA models. For example, the 9009-22G reports as "EP11"
instead of "EP51". This mismatch can prevent 3rd party software
licenses from working.
The system has to be re-IPLed for the fix to take effect. This
pertains to 9009-xxG models only that are being upgraded from FW941.00.
Note: If 3rd party software licenses were installed based
on the old incorrect QPRCFEAT QMODEL value, new licenses will be needed
to work with the updated value.
|
4.0 How to
Determine The Currently Installed Firmware Level
You can view the server's
current firmware level on the Advanced System Management Interface
(ASMI) Welcome pane. It appears in the top right corner. Example:
VL910_123.
5.0
Downloading the Firmware Package
Follow the instructions on Fix Central. You must read and agree to the
license agreement to obtain the firmware packages.
Note: If your HMC is not internet-connected you will need to
download the new firmware level to a USB flash memory device or ftp
server.
6.0 Installing the
Firmware
The method used to install new firmware will depend on the release
level of firmware which is currently installed on your server. The
release level can be determined by the prefix of the new firmware's
filename.
Example: VLxxx_yyy_zzz
Where xxx = release level
- If the release level will stay the same (Example: Level
VL910_040_040 is currently installed and you are attempting to install
level VL910_041_040) this is considered an update.
- If the release level will change (Example: Level VL900_040_040 is
currently installed and you are attempting to install level
VL910_050_050) this is considered an upgrade.
HMC Managed Systems:
Instructions for installing firmware updates and upgrades on
systems managed by an HMC can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eh6/p9eh6_updates_sys.htm
NovaLink Managed
Systems:
A NovaLink managed system does not have a HMC
attached and is managed either by PowerVM Novalink or PowerVC using
PowerVM Novalink.
Instructions for installing firmware updates and upgrades on systems
managed by PowerVM NovaLink can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eig/p9eig_updating_firmware.htm
HMC and NovaLink
Co-Managed Systems:
A co-managed system is managed by HMC and NovaLink,
with one of the interfaces in the co-management master mode.
Instructions for installing firmware updates and upgrades on systems
co-managed by an HMC and Novalink is the same as above for a HMC
managed systems since the firmware update must be done by the HMC in
the co-management master mode. Before the firmware update is
attempted, one must be sure that HMC is set in the master mode using
the steps at the following IBM KnowledgeCenter link for NovaLink
co-managed systems:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eig/p9eig_kickoff.htm
Then the firmware updates can proceed with the same steps as for
the HMC managed systems:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9eh6/p9eh6_updates_sys.htm
Systems not Managed by an HMC or NovaLink:
Power Systems:
Instructions for installing firmware on systems that are not
managed by an HMC can be found at:
https://www.ibm.com/support/knowledgecenter/9009-22A/p9ha5/fix_serv_firm_kick.htm
Systems running Ubuntu operating system:
If Ubuntu will be used to update the system firmware, please
follow these instructions to extract the installable binary and
update/upgrade the firmware:
1) Download the .gz (tarball) from Fix Central to your Ubuntu system
(ie, to /tmp/fwupdate).
2) Extract the .gz file to /tmp/ on the Ubuntu system:
Example:
tar -xzf /tmp/fwupdate/01VL910_040_040.tar.gz -C
/tmp/fwupdate
3) Use update_flash -v -f <extracted file name> to verify the
package.
4) Update your firmware using update_flash:
/usr/sbin/update_flash -f <extracted file name>
System will reboot during the firmware update. When the system reaches
Ubuntu run-time state, you can then commit or reject the firmware
update:
Commit: /usr/sbin/update_flash -c
Reject: /usr/sbin/update_flash -r
IBM i Systems:
For information concerning IBM i Systems, go to the following
URL to access Fix Central:
http://www-933.ibm.com/support/fixcentral/
Choose "Select product", under
Product Group specify "System i", under Product specify "IBM i", then
Continue and specify the desired firmware PTF accordingly.
7.0 Firmware History
The complete Firmware Fix History (including HIPER descriptions)
for this Release level can be reviewed at the following url:
http://download.boulder.ibm.com/ibmdl/pub/software/server/firmware/VL-Firmware-Hist.html
8.0
Change History
Date
|
Description
|
September 15, 2021 |
Added a defect statement:
Added support in ASMI for
a new panel to do Self -Boot Engine (SBE) SEEPROM validation. This
validation can only be run at the service processor standby
state.
If the validation detects a problem, IBM recommends the system not be
used and that IBM service be called. |
May 17, 2021
|
- Fix descripton text updated.
- Added a new section 2.5 NVDIMM Updates.
|