FIRMWARE CHANGE HISTORY ----------------------- Lenovo RackSwitch G8272 Version 8.2.3.0 (Released July 2015) ** changes since release 8.2.2.0 ** Enhancemnets: none Changes: - SNMP Traps for the VLAG feature were now included in the Enterprise MIB. (LV310110) - A new command ‘no update-internal’ has been added to stop sending VSIDB updates. (LV310500) Fixes: - A crash could occur when a user tries to add more than the allowed number of members supported to a zone on the switch via BBI. (LV304441) - The SNMP Object entPhysicalMfgName (1.3.6.1.2.1.47.1.1.1.1.12) returned the string “IBM”. It has been fixed to return “Lenovo”. (LV310182) - The port numbering scheme in the commands "show transceiver" and "show interface traceiver" is inconsistent after configuring an interface in breakout (4x10G) mode. (LV310036) - Spanning Tree Protocol could flap and virtual ports could go down when CEE is enabled and heavy traffic is directed from the uplink ports to the virtual ports. (LV310135) - A TFTP copy of an invalid running-config to the switch that contained reserved VLANs of a vmgroup was not producing any error message to the user. (LV302258) ================================================================================ Lenovo RackSwitch G8272 Version 8.2.2.0 (Released May 2015) ** changes since release 8.2.1.0 ** Enhancemnets: none Fixes: - Switch fails to add/remove VLANs from a port via SNMP using objects vlanNewCfgAddPortIndex (.1.3.6.1.4.1.19046.2.7.24.2.1.1.3.1.5) and vlanNewCfgRemovePortIndex (.1.3.6.1.4.1.19046.2.7.24.2.1.1.3.1.6) (LV307631/LV307641) - Switch could fail to install an ARP Entry for the static route or gateway leading to ARP packets getting flooded in the network. (LV301211) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2015-2808 (BarMitzvah),CVE-2015-0286 (ASN1_TYPE_cmp) (LV308595, LV307463) Changes: - New objects hwPowerSupplyState (.1.3.6.1.4.1.19046.2.7.24.1.3.1.41.0), hwSerialNumber (.1.3.6.1.4.1.19046.2.7.24.1.3.1.18.0) and hwManufacturingDate (.1.3.6.1.4.1.19046.2.7.24.1.3.1.19.0) have been added to the enterprise MIB. The Description clauses for the objects hwFanSpeed (.1.3.6.1.4.1.19046.2.7.24.1.3.1.13.0) and hwTempSesnors (.1.3.6.1.4.1.19046.2.7.24.1.3.1.14.0) have been changed. (LV307604) ================================================================================ Lenovo RackSwitch G8272 Version 8.2.1.0 (Released March 2015) Initial Release.