FIRMWARE CHANGE HISTORY ----------------------- Lenovo RackSwitch G8296 Version 8.2.4.0 (Released October 2015) ** changes since 8.2.1.0 ** Enhancements: none Changes: - The object sFlowVersion (1.3.6.1.4.1.14706.1.1.1.0) returned IBM in the Organization clause instead of Hitachi. (LV301941) - The Protocols SSH and SLP (Service Layer Protocol) are enabled by default on the switch. (38987,10224) - The command "show flash-dump-uuencode" in the isCLI menu and its equivalent "/maint/uudmp" from the IBMNOS-CLI menu have been deprecated. The reference to use this command has been removed from the help tip that is posted upon user login if a flash-dump exists on the switch. (XB282980) - Extended the ability to support Dual Speed 1/10G MMF SFP+ Transceivers. (LV311542,LV311078,LV312616) Fixes: - The user is incorrectly prompted for "setup configuration" upon login even though configuration had been applied and saved, and the startup configuration block was set to active. (39158) - When configuring “qos bandwidth min” on an UFP port, the switch would incorrectly allow the sum of the minimum bandwidth to be less than 100%. (40181,40295) - The output of “show tech-support” now includes the isCLI commands as headers before their respective output. (38125) - If the serial number of the switch was changed, the user was prevented from successfully installing a new image, and the message “image contains invalid signature” would be displayed. (40638) - Multicast DA (Directory Agent) Advertisements received on the Management ports are accounted as Unicast Advertisements. (41080) - Fixed OpenSSL vulnerabilities as reported in CVE Advisories CVE-2015-1788 (BN_GF2m_mod_inv),CVE-2015-1789 (X509_cmp_time) and CVE-2015-1792 (do_free_upto). (39415) - Fixed security vulnerabilities as reported in CVE Advisories CVE-2015-4000(Logjam, TLS protocol) // red releases only (LV311132) ================================================================================ Lenovo RackSwitch G8296 Version 8.2.1.0 (Released June 2015) Initial Release.