=============================================================================== Emulex NIC Device Driver for Linux ===============================================================================
Driver Version: 4.6.267.4 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 KVM configurations - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 SR-IOV configurations - SR-IOV configuration section of the Linux NIC Driver Documentation has been modified to improve clarity
Incremental Interoperability: - S3 Resume on IBM Flex - SLES 11.3 on IBM System x and BladeCenter
Known Issues: - SRIOV is supported with the following Linux distributions: RHEL 6.3 and 6.4 64 bit RHEL 6.3 and 6.4 64 bit with KVM (guest support is dependent on the Emulex driver version present in the guest)
SLES11 SP2 and SP3 64 bit SLES11 SP2 and SP3 64 bit with KVM (guest support is dependent on the Emulex driver version present in the guest)
Use of SR-IOV with the XEN hypervisor is not supported at this time Use of SR-IOV with the KVM hypervisor requires the use of macvlan interfaces
Device Driver Version: 4.6.148.0 (Supported on IBM System x & BladeCenter)
Problems Fixed: - Ethernet performance issues in a variety of workloads - VFs are not displayed after driver re-load when is VFs attached to VM - vLAN tagging in Switch Agnostic vNIC mode
Incremental Interoperability: - RHEL 5.9 - RHEL 6.4 - Network performance varies with workload. An ethernet driver tuning script and instructions is now included with the be2net driver. - Switch Independent Mode within hypervisor OS's
Known Issues: - Multi-channel is not supported in RHEL5.x XEN. This is a kernel limitation - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 KVM configurations - Under certain conditions, performance issues may be seen with multi-channel in RHEL6.4 SR-IOV configurations - SR-IOV is not supported with RHEL5.x XEN
Driver Version: 4.4.180.0 (Previously supported on IBM Flex) Driver Version: 4.2.389.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed: - Unloading the driver hangs the system after running IPv6 traffic - Link status messages cleaned up when in Switch Agnostic mode - Miscellaneous network performance issues to improve throughput - Miscellaneous problems related to SRIOV to improve usability - Ethtool wol command displays wol enabled even when disabled - Ethtool speed reported as 10000Mb/s for disabled devices in Switch Agnostic mode
Incremental Interoperability: - RHEL6.3 GA Kernel - Increase default B/W for SRIOV vf's to 10Gb from 100Mb
Known Issues: - SR-IOV configuration section of the Linux NIC Driver Documentation will be modified as follows to improve clarity (noted by << >>):
11. Use the Virtual Machine Manager GUI to attach the VF (step 7 on page 34) to the guest operating system by using the add physical device option.
<< Note 1: If user wants to re-configure an already configured setup, it can be done by removing the attached VF from the respective guest operating system using the remove option after selecting the VF attached. And then attaching another VF (step 11).
Note 2: Consult the documentation for your host operating system for help using the Virtual Machine Manager to attach and detach virtual interfaces. >>
12. Start the RHEL 6.x guest operating system. Once the guest operating system is booted, use the lspci command to confirm the visibility of the OneConnect NIC function. The output shows a OneConnect NIC function, for example: 03:00.0 Ethernet controller: Emulex Corp. Emulex OneConnect 10Gb NIC (be3)
13. The OneConnect Ethernet driver automatically loads with the inbox driver, and creates the network interfaces. Use the ifconfig command to verify that the interface is created.
14. After configuring the network interfaces with proper IP addresses, you can send and receive network traffic from the VM. << (Consult the documentation for your host and guest operating systems for network configuration help).>>
Driver Version: 4.1.413.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- WOL changes for Linux NIC driver as mentioned in Bug# 24543 - SR IOV UE when attempt to do multiple (3 times) driver load/unload - Speed is 10000Mb/s for Disabled devices in UMC Mode - Incorrect Duplex value is shown for unconnected port of NC552m in Rhel6.1 32bit - SLES 11 SP2 GMC: Enable support for Lnx NIC Driver - SRIOV: When VGT is configured for a VF, ip link show doesn't display it for the VF configured. - RHEL 5.8 GA: Enable support for Lnx NIC Driver - ip link command with vlan = 4095 has toggling effect - ip link command with vlan =0 should remove guest VGT privilege
Driver Version: 4.1.334.39 (Previously supported on IBM SystemX & BladeCenter)
- SR-IOV: Can't load be2net driver in a VM after the VM has been rebooted - SR-IOV: Unload PF driver with VF driver loaded causes system instability - SR-IOV: VF MAC always gets Emulex OUI - SR-IOV: Partition the limited per port VLAN entries across VFs and PFs - Non Member VLAN packets not received in interface promiscuous mode in BE3 - Avoid CQ full condition in HW - be2net: use RX_FILTER cmd to program multicast addresses - account for skb allocation failures in ethtool stats - Support 60 second delay to Linux NIC driver to allow FAT dump completion on recovery from EEH - Link status is up [ethtool and OCM] when the bandwidth is assign 0 for UMC configuration - Remove msix module parameter - Use V1 version of COMMON_NTWK_LINK_STATUS_QUERY for Lancer. - Emulex: Ethtool failing to update FW - Emulex: Panic in be2net driver in SLES11-SP2-B7 on adapter - TCP ACKs from different connections are getting received in single queue - Multicast filtering feature not working on PPC - Exit of mcast promiscous mode not working - VLAN promiscous mode cannot be set on Lancer - Can't communicate after changing MAC address via VLAN interface - Improper memory accounting in received packets - WOL changes for Linux NIC driver as mentioned in bug - Transparent VLAN tagging feature not working in SR-IOV elx_dd_nic_ibm1212-4_6_267_4-4_rhel5_32-64_chg
=============================================================================== Emulex iSCSI Device Driver for Linux ===============================================================================
Driver Version: 4.6.267.4 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - RH5.9 kernel panic after rebooting the OS
Device Driver Version: 4.4.175.0 (Previously supported on IBM Flex)
Problems Fixed: - Cleaned up a cosmetic problem with warning messages during driver compile from source - System crashes when we run simultaneous IO to 6 vNIC’s with iSCSI IO - Linux kdump kernel crashes during shutdown after capturing dump, if be2iscsi driver running
Driver Version: 4.1.402.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- LUN is not getting detected for OEM CNA in SLES 11 SP2 64 bit OS - ioctl semaphore deadlock when running load/unload loop with target - SLES 11 SP2 GMC: Enable support for Lnx iSCSI Driver - RHEL 5.8 GA: Enable support for Lnx iSCSI Driver
Driver Version 4.1.334.39 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Emulex: Warning messages seen while building Emulex drivers on RHEL platform - Unable to load be2iscsi driver during iSCSI boot OS install - Modprobe be2iscsi hangs when system with max targets login - be2iscsi unload hangs the system - fw rebooted on 1st mbox cmd after driver load > unload > load - Failed to initialize iscsi driver - need to define DMA_32BIT_MASK / DMA_64BIT_MASK in Linux kernel 3.x.x elx_dd_iscsi_ibm1212-4_6_267_4-4_rhel6_32-64_chg
MLNX_OFED 2.0-2.6.7 provides the following changes and new features:
- SR-IOV for both Ethernet and InfiniBand *A ConnectX-3 HCA capability. - RoCE over SR-IOV - eIPoIB to enable IPoIB in a Para-Virtualized environment (at Beta level) - HPC performance enhancement: - Contiguous pages - internal memory allocation improvements - Contiguous pages - register shared memory - Contiguous pages - control objects (QPs, CQs) - Ethernet Performance Enhancements (NUMA Related and others) for 40G and 10G - Ethernet Time Stamping (at Beta level) *A ConnectX-3 HCA capability. - Flow Steering for Ethernet and InfiniBand. *A ConnectX-3 HCA capability. - Raw Eth QPs: - Checksum TX/RX - Flow Steering - Errata Kernel upgrade support - YUM update support - Storage – iSER and SRP - 64bit wide counters (port xmit/recv data/packets unicast/mcast) - VERSION query API: library and headers mlnx_fw_nic_2_0-2_6_7_1_rhel6_x86-64_chg
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.3.0 Latest Driver Version: 3.2.3.0 Document Updated: 09/20/2013 Product: Brocade FC HBA / FCoE CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for Linux PTP - Support for UEFI Health Check Protocol - Support for SLES11SP3
Version 3.2.1.1 Fixes and Enhancements: - Firmware update to address the thermal notification issue
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381" - Support for RHEL5.9 and RHEL6.4
Fixes and Enhancements: - Enhanced Linux driver data path to properly handle IPv6 packets. - Enhanced Linux driver to make sure user configured path tov value is persistent and is not changed due to change in dev_loss_tmo.
New Features and Feature Enhancement: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Fixes and Enhancements: - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Version 3.1.0.0 Key features and enhancements supported for the software release 3.1.0.0 include the following:
New Features: - D-port support between Brocade 16Gb HBAs and Brocade 16Gb FC switch platforms with FOS v7.0.1 and later releases - FC-AL support for direct attach to storage - Ability to assign minimum bandwidth to each vNIC - Queue Depth adjustment - FC QoS set by percentage - Performance enhancements in Ethernet drivers - Technology Preview support of 1860 HBA on Power PC architecture
Fixes or Enhancements: - Resolved an issue where HCM Agent may not start if BR1860 adapter is configured in NIC mode. - Improved stability with Hyper-V and Teaming configurations. - Resolved I/O errors when running traffic with Brocade HBAs(models 415, 425, 815, 825, and 804), if the server’s PCI max read request size is configured to be 2K or greater with PCI Gen2x8.
Version 3.0.0.0 Fixes and Enhancements: - Added support for Brocade 1860 AnyIO Fabric Adapter (User configurable port mode - FC or NIC or CNA) - Added Fibre Channel 16G Support - Enabled Fabric Assigned Address in Fibre Channel Fabric - Added PF based Virtualization – vHBA - Enhanced CLI, HCM GUI and CIM support in inbox drivers. - Added PF based Virtualization - vNIC - Added iSCSI over DCB Support - Added Multiple Tx Priority Queues Support - Added SNMP Support
Version 2.3.0.3 Fixes and Enhancements: - Enhanced SNIA API to report port speed of 4 and 8Gbps in SNIA format. - Enhanced XIV array interoperability that addresses a data integrity corner case. - Enhanced the transmit path handling in Linux Network Driver to avoid a corner case that could lead to transmit path stall. - Enhanced the Linux Adapter Software installer script to update the initrd with the correct name even when there are multiple copies of the OEM specific initrd(s).
Version 2.3.0.0 Enhancements: - Enabled HP DL120 server to support Boot over SAN with two Brocade HBAs installed. - Improved network driver CPU and performance optimization. - Enabled automated target and LUN discovery of enterprise HDS storage once LUN masking has occurred. - Improved Tivoli interoperability to meet device display requirements.
Version 2.2.0.1 Added capability to handle ADISC frames. Unhandled ADISC use can cause SAN boot failure when booting from IBM storage array.
Version 2.2.0.0 Adds support for bootcode updates to Bladecenter 10G Converged Network Adapters
Version 2.1.0.0 Adds support for bootcode updates to 10G Converged Network Adapters
Version 2.0.0.0 Initial release for 4/8G FC HBAs brcd_dd_fc_bfa-3_2_3_0_rhel6_32-64_chg
Dynamic System Analysis (DSA) Preboot Change History
Version 9.30, Build ID DSYTB27 o New System Support: Flex System x440 Compute Node (7917, 2584) IBM System x3300 M4 (7382) o Problem(s) Fixed: 1. PMR - 05766,YL2,760 Aenservice appeared after running UpdateXpress & DSA. 2. PMR - 05193,W01,000 7147 - Intermittent random PSOD in vmware. multiple
o Enhancement: None o Limitations: - FIFO test of NIC diagnostics is not supported on the Intel I350 Quad Port GbE. Powerville has shared FIFO and shared FIFO registers making a test impossible if four ports are running at once. - For more limitations please refer to readme. o Special usage: - 2012 ToolsCenter 12D
Version 9.29, Build ID DSYTAB6 o New System Support: Flex System x440 Compute Node (7917, 2584) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - NGP-4Q(12B+ FixPack3)
Version 9.28, Build ID DSYTAA4 o New System Support: x3630 M4 (7519) x3550 M4 (7383) o Problem(s) Fixed: None o Enhancement: None o Limitations: - DSA implemented signature in product build. Please update IMM to 1AOO34V or later before updating pDSA, or flash failure will occur; - The user can not flash Embedded Preboot on VMware ESX3.5 prior to U4. - When flashing DSA Preboot using wflash/lflash, if you notice a build mismatch error, please make sure IMM firmware level is minimum 29B. Once you upgrade the IMM firmware to 29B or higher, DSA Preboot will continue to flash without error; - For more limitations please refer to readme. o Special usage: - IMMV2 system 2012 4Q-LFC
Version 9.27, Build ID DSYTA7F o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme o Special usage: - IMMv1 system 2012 4Q-LFC
Version 9.26, Build ID DSYTA6G o New System Support: None o Problem(s) Fixed: None o Enhancement: DSA Performance Optimization o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12C
Version 9.21, Build ID DSYTA1U o New System Support: None o Problem(s) Fixed: 1.Recovered LSI Rawdata: "MegaCli -FwTermLog -Dsply -aALL" o Enhancement: None o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B Plus
Version 9.20, Build ID DSYTA0R o New System Support: x3530 M4 (7160) x3630 M4 (7158) x3750 M4 (8722, 8733) HS23E (8038, 8039) Flex System x220 Compute Node (7906, 2585) o Problem(s) Fixed: 1. PMR 05819,YL2,760 An error occured during the execution of DSA on Windows, DSA exits with an error at the eventlog plugin. o Enhancement: 1. Add HW remote presence key collection for High volume systems. o Limitations: Refer to readme o Special usage: - 2012 ToolsCenter 12B
Version 9.07, Build ID DSYT9CA o New System Support: x3750 M4 (8722, 8733) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.06, Build ID DSYT9BC o New System Support: Flex System x220 Compute Node (7906) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.05, Build ID DSYT9AA o New System Support: x3630 M4 (7158) x3530 M4 (7160) x3100 M4 Refresh1 (2582) x3250 M4 Refresh1 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.04, Build ID DSYT99E o New System Support: Flex System x240 Compute Node (8737, 8738, 7863) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.03, Build ID DSYT98I o New System Support: HS23E (8038, 8039) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.02, Build ID DSYT97C o New System Support: iDataPlex dx360 M4 server/2U chassis (7912/7913) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Version 9.01, Build ID DSYT96D o New System Support: x3500 M4 (7383) x3550 M4 (7914) x3650 M4 (7915) o Problem(s) Fixed: o Enhancement: None o Limitations: None o Special usage: None
Version 9.00, Build ID DSYT95W o New System Support: BladeCenter HS23 (7875) BladeCenter HX5 (7873, 1910) Flex System x240 Compute Node (8737, 8738, 7863) Flex System Manager Node (8735) x3500 M4 (7383) x3550 M4 (7914) x3630 M4 (7158) x3650 M4 (7915) x3690 X5 (7192, 7147) x3850 X5 / x3950 X5 (7143, 7191) o Problem(s) Fixed: 1. PMR 24817,8QG,000, PMR 30680,499,000 After kicking off DSA on one of the management nodes (x3650 M2) of SONAS 1.2(RHEL5 based), the node became unresponsive and dropped out of the cluster.
2. PMR 53575,000,834, PMR 05961,YL4,760 After running DSA, when using linux dump command on a DDS5 usb internal tape drive attached in x3650M2 backup speed becomes very slowly or failed.
3. PMR 26905,095,866 Running DSA 4.0 as well as DSA 3.4 on x3850 X5 the server is freezing, users have to reboot the server.
4. DSA 4.00 and previous version segmentation fault issue
6. PMR 15086,OTH,760 DSA 9.00 with --no-imm-lan option does not work correctly on RHEL5.3. The USB port state is changed during the execution of DSA.
o Enhancement: 1. Add GUI and CLI menu for Features on Demand (FoD) Activation Key Management o Limitations: Refer to readme. o Special usage: None
Version 4.02, Build ID DSYT92I o New System Support: iDataPlex Direct Water Cooled dx360 M4 server o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 4.01, Build ID DSYT92H o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 4Q lifecycle
Version 4.00, Build ID DSYT91S o New System Support: None o New server options support: None o Problem(s) Fixed: 1. PMR 15065,OTR,760 On Unisys ES7000 or x3850 X5, the Memory Card number with failed DIMM can not be reported in IPMI Eventlog if the Memory Card is bigger than 4.
o Enhancement: 1. Added > 1TB memory test support o Limitations: Refer to readme. o Special usage: - 2011 ToolsCenter 11D
Version 3.48, Build ID DSYT89PUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - 2011 3Q lifecycle
Version 3.47, Build ID DSYT89LUS o New System Support: x3100 M4 (2582) x3250 M4 (2583) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.46, Build ID DSYT89GUS o New System Support: System x iDataPlex dx360 M3 (6391) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.45, Build ID DSYT89EUS o New System Support: None o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: - x3850 X5 / x3950 X5 (7143, 7191) EXA scaling
Version 3.43, Build ID DSYT87HUS o New System Support: BladeCenter HX5 (7873,1910) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.43, Build ID DSYT87FUS o New System Support: x3850 X5 / x3950 X5 (7143, 7191) x3690 X5 (7192, 7147) o Problem(s) Fixed: o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.40, Build ID DSYT85T o New System Support: BladeCenter HS22 (1911) x3650 M3 (5454) o Problem(s) Fixed: None o Enhancement: None o Limitations: Refer to readme. o Special usage: None
Version 3.30, Build ID DSYT80S o New System Support: None o Problem(s) Fixed: None o Enhancement: 1. Correct a problem with LSI MegaRAID reporting for IBM Service o Limitations: Refer to readme. o Special usage: None
Version 3.20, Build ID DSYT75X o New System Support: x3630 M3 (7377) x3690 X5 (7148, 7149) o Problem(s) Fixed: None o Enhancement: 1. Add LSI Hard Disk Drive (HDD) diagnostic back for both the onboard SAS chip and ServeRAID o Limitations: - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Verion 3.20, Build ID DSYT75U o New System Support: x3755 M3 (7164) o Problem(s) Fixed: None o Enhancement: None o Limitations: None o Special usage: None
Verion 3.10, Build ID DSYT70X o New System Support: x3400 M3(7378, 7379) x3500 M3(7380) x3550 M3 (7944, 4254) x3620 M3 (7376) x3650 M3 (7945, 4255) x3690 X5 (7148, 7149) x3850 X5 Standard Single-node and Multi-node models(7145, 7146) x3950 X5 Specially configured Database Engine models (7145, 7146) iDataplex dx360 M3 (6391) HS22V (7871,1949) HX5 (7872, 1909) o Problem(s) Fixed: None o Enhancement: 1. Added ServeRAID data collection o Limitations: - The following function has been temporarily removed from DSA Preboot for both the onboard SAS chip and ServeRAID: - LSI Hard Disk Drive (HDD) diagnostic - If you have ServeRAID (M1015) SAS/SATA Controller, 46M0831 installed, you will need one of the following: - uEFI GYE133A or greater for x3200 M3 and x3250 M3 - uEFI Y4E145B or greater for x3400 M2, x3400 M3, x3500 M2 and x3500 M3 - uEFI D6E145C or greater for x3550 M2, x3550 M3, x3650 M2 and x3650 M3 - For more limitations please refer to readme o Special usage: None
Version 3.02.56, Build ID DSYT56e o New System Support: None o Problem(s) Fixed: None o Enhancement: - The following systems are supported when BoMC downloads the corresponding system enablement pack: HS22V (7871,1949) x3550 M3 (7944,4254) x3650 M3 (7945,4255) x3400 M3 (7378,7379) x3500 M3 (7839) dx360 M3 (6391) o Limitations: - No HDD diagnostics available - To ensure quality and stability of the DSA code, we have reverted some display functionality of RAID information to what was shown in previous versions of DSA. This affects RAID display on the following adapters: Megaraid 8480 Serveraid MR10i Serveraid MR10is Serveraid MR10m Serveraid MR10k Serveraid M1015 Serveraid M5014 Serveraid M5015 On these adapters, the RAID information is generated from the output of separate command line tools and the format may not match other output in DSA. - For more limitations please refer to readme o Special usage: None
Version 3.00, Build ID: DSYT55a o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7327, 7328, 4251, 4252, 4261 o Limitations: - No HDD diagnostics available - For more limitations please refer to readme o Special usage: None
Version 1.16, Y4YT19AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7839, 7836, 7837 o Limitations: None o Special usage: None
Version 1.15, TMYT20AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7321, 6380, 7323 o Limitations: None o Special usage: None
Version 1.14, D6YT37AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7946, 4198, 7947, 4199 o Limitations: None o Special usage: None
Version 1.13, P9YT48AUS o New System Support: None o Problem(s) Fixed: None o Enhancement: - Added support for Machine Types 7870, 1936, 7809 o Limitations: None o Special usage: None
Version 1.00 - Initial release
(C) Copyright International Business Machines Corporation 2008 - 2012. All rights reserved. ibm_fw_dsa_dsytc4p-9_44_anyos_anycpu_chg
Integrated Management Module II (IMM2) Firmware Update Change History
Version 3.78, 1AOO52Y - Critical Fixes: -- Fixed a potential security vulnerability with information contained in service data (refer to security bulletin CVE-2014-0882) -- Fixed a potential security vulnerability with Trusted Platform Module (TPM) initialization settings (refer to security bulletin CVE-2014-0881)
Version 3.67, 1AOO50G - Supports System x3650 M4 BD, Machine Type: 5466
Version 3.65, 1AOO50D NOTE: If you have a System x3550 M4 with the "Emulex VFA Mezz card" and a ==== single processor, don't update the IMM2 with this firmware - Critical Fix: -- Fixed a problem on the System x3650 M4 server where the system shuts down due to a false temperature event from the ambient temperature sensor - Fixed a problem where the IMM2 may erroneously report a fan fault in the x3630 M4 when the system is powering on. See RETAIN tip H207461 for the description of the original problem - Fixed a screen refresh problem where it occurs after resetting IMM2 - Fixed a firmware problem that may cause the IMM2 to reset unexpectedly - Fixed a problem where the IMM2 SNMP interface may intermittently be unavailable if the system is running VMWARE ESXi 5.x - Fixed a problem where the CPU may potentially throttle in the x3650 M4 system with two 550 watt power supplies and one hard drive backplane
Version 3.60, 1AOO50C - Added support for the Intel IvyBridge-EP CPU on the HS23 blade - Fixed a problem where the HS23 hard drive number reported in the AMM event did not match the drive number on the physical blade enclosure - Fixed an intermittent problem where the UXSPI update utility may erroneously report that the firmware image is not meant for the HS23 system - Fixed a problem that causes the AMM web interface to not display properly when drives are removed or inserted - Fixed a problem where the IMM2 may not detect an over temperature condition for a DIMM
Version 3.56, 1AOO50K - Fixed a Flex Systems Manager (FSM) Configuration Patterns problem where configuration deployments would fail with an activation job error message: ERROR: LDAP failed with rc=102 ERROR: LDAP failure: SYSPROF_LDAP_BIND_FAIL INFO
Version 3.55, 1AOO50E - Fixed an issue so a fully qualified domain name can be used for a syslog collector in addition to an IP address - Fixed an issue to allow a user the ability to specify the port to use for syslog notifications, rather than only supporting the default port
Version 3.50, 1AOO50B - Fixed an issue where the default static IPv4 address was assigned to the IMM2 management interface instead of the user configured static IPv4 address in DHCP fallback to static mode, if the DHCP server was not available - Prevent a VLAN from being configured on the IMM2 management interface for Flex nodes - Fixed a problem where the CPU throttling state recovery indication to the FSM might not be properly reported - Corrected an issue with the launch of the IMM2 Remote Console operation that required a restart of the IMM2 - Corrected the firmware to apply the inactivity timeout to web pages that automatically refresh - Updated the web browser support. The following web browsers are supported: Firefox 3.6-20 Chrome 13-26 Internet Explorer 8-10 - Added support for the S3 Sleeping State to the IMM2 user interfaces on those servers that include the S3 feature - Added changes to use the minimum TLS version setting that is provisioned by the CMM in Flex for encrypted communication - Enhanced the content of the service data file to assist in problem determination - Added a option to have the IMM2 automatically copy the firmware from its primary bank into the backup bank after the firmware has been run for a period of time and proven itself to be stable - Enhanced the IMM2 firmware to automatically restore itself without the need for user intervention if the firmware becomes corrupted - Added new commands on the command line interface to stop a serial redirection operation that is currently in progress, and to report the user names that have a serial redirection operation started - Added changes to use the DNS settings that are provisioned by the CMM in Flex to support use of an LDAP hostname for authentication - Updated the firmware to log hardware inventory change informational messages - Added support for the Service Advisor feature on stand alone rack servers to automatically call for service when a repair is needed - Added support to configure the Ethernet-over-USB IP address using ASU - Added changes to support the thermal requirements for new Solid State Drives used with the ServeRAID M5100 Series IBM Flex System Flash Kit v2 - Updated the IMM2 date and time web page on Flex nodes to only display the current date and time - Updated the SSH firmware to address various OpenSSH vulnerabilities that have been identified by security community - Added changes to support the Web Services-Management protocol
Version 3.40, 1AOO48M - Supports System x3250 M5, Machine Type: 5458
Version 3.37, 1AOO48P - Added support for the IBM NeXtScale Storage Native Expansion (NeX) Tray for IBM NeXtScale nx360 M4
Version 3.36, 1AOO48Q - Fixed a problem on System x iDataPlex dx360M4 where a CIM client cannot get needed event information for asserted events
Version 3.35, 1AOO48N - Critical Fix: -- Corrected a problem on the System x3650 M4 and x3650 M4 HD servers causing the system to shut down due to an erroneous critical temperature event reported by the ambient temperature sensor
Version 3.30, 1AOO48L - Fixed a problem on System x iDataPlex dx360M4 where nodes shutdown due to a critical temperature event from the Ambient Temp sensor
Version 3.20, 1AOO48K - Supports System NeXtScale nx360 M4, Machine Type: 5455
Version 3.10, 1AOO48H - Added support for System x3650 M4 HD, Machine Type 5460 - Added support for newer CPUs in the System x iDataPlex dx360M4, x3500M4, x3550M4, and x3650M4 servers - Added a feature on the System x3550 M4 and x3650 M4 to fail over from the dedicated systems management network port to the shared port when the dedicated network link is not available - Fixed a problem where an NTP update message is logged every 1440 minutes - Fixed a problem where the IMM2 web interface won't accept an NTP hostname string that starts with a numeric character - Fixed a problem where the LDAP Group Filter authentication does not work as expected - Fixed a problem where the IMM2 reports 0 Watts when the System x iDataPlex dx360M4 is DC cycled or resumes from the S3 sleep state - Fixed an Ethernet problem that may cause an IMM2 failure to establish a link when the Ethernet speed and duplex settings are not configured to use auto-negotiation
Version 2.60, 1AOO42Y NOTE: For increased security, only high strength ciphers are now supported when using https.
==== Your browser must support one of the following cipher suites: | HE-RSA-AES256-SHA256 TLSv1.2 Kx=DH Au=RSA Enc=AES(256) Mac=SHA256 DHE-RSA-AES256-SHA SSLv3 Kx=DH Au=RSA Enc=AES(256) Mac=SHA1 AES256-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA256 AES256-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(256) Mac=SHA1 DHE-RSA-AES128-SHA25 TLSv1.2 Kx=DH Au=RSA Enc=AES(128) Mac=SHA256 DHE-RSA-AES128-SHA SSLv3 Kx=DH Au=RSA Enc=AES(128) Mac=SHA1 AES128-SHA256 TLSv1.2 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA256 AES128-SHA SSLv3 Kx=RSA Au=RSA Enc=AES(128) Mac=SHA1
- Added support for the IBM Flex System x222 Compute Node - Improved Remote Presence (keyboard, mouse and virtual media)and in-band management (LAN-over-USB) performance - Changed the default file name for the Service Data file (First Failure Data Capture or FFDC) on the web interface to incorporate the machine type, serial number and a timestamp - Updated the IMM2 PCIe Bridge Firmware to support Windows 2012 Certification - Improved IMM2 Reliability, Availability, Serviceability (RAS) Features: - Added component and system VPD integrity checking & reporting - Enhanced Service Data collection (FFDC)
- Enhanced the configuration of UEFI settings via the CIM interface for applications like IBM Systems Director - Added Sub-manufacturer inventory support for mezz card and Sub-manufacturer inventory support for the system for IBM Systems Director - Added the UUID for the PCIe Expansion Node and the Storage Expansion Node to the SLP attributes reported by the IMM2 - Added the number of enabled CPU core and the Static power savings mode support for IBM Systems Director - Enhanced the alert recipient email notification, firmware update, event log, log out, and hardware information web pages to improve usability - Added support for IPMI & SNMPv3 accounts to be centrally managed by the Flex Chassis Management Module - Fixed a problem where an invalid configuration was erroneously reported for an unpopulated CPU socket in the IBM Flex System x440 - Enabled users to configure a longer trespass message - Increased the length of the LDAP group filter field to 511 characters - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems energy pack monitoring - Corrected a problem with ServeRAID M5115 SAS/SATA Controller for IBM Flex Systems LED management - Added IPMI command to configure the LAN-over-USB IP address
Version 2.52, 1AOO42E - Critical Fix: -- Fixed a problem on the System x3300 M4 servers causing the system to shut down due to a critical temperature event reported by the ambient temperature sensor
Version 2.50, 1AOO40Z - Added support for the Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter, and Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x3550 M4 and x3650 M4 NOTE: UEFI also needs to be upgraded to D7E128B (v 1.40 or newer, for the x3550 M4) or VVE128B (v1.40 or newer, for the x3650 M4) to support these cards - Added support for the Mellanox ConnectX-3 Dual Port QDR/FDR10 mezzanine card and Mellanox ConnectX-3 VPI Single-port QSFsorry.P FDR14/40GbE HCA on System x3550 M4, and x3650 M4 - Added optional Fan Zone support for single CPU systems (x3550 M4 and x3650 M4) with an installed with Qlogic Dual Port 10GbE SFP+ Embedded VFA - Fixed an intermittent problem where a Gratuitous ARP is not sent successfully - Fixed a problem where after the IMM2 firmware is flashed, there is a slight chance that the IMM2 web server can't be accessed when AC power is reapplied - Disabled the weak cipher suit used in the SSL/TLS firmware with the https protocol to avoid potential security vulnerabilities - Fixed a problem on the System x3750 M4 where the IMM2 shared mode network connection will be lost after upgrading the firmware of the onboard Emulex BE3 controller - Fixed a problem on the HS23 where the OS watchdog timer doesn't work - Fixed a problem on the HS23 where the Fault LED occasionally lights when the chassis is powered on with the BPE4 - Fixed a problem on the HS23 where the server may shut down after resetting the IMM2 - Enhanced the messaging mechanism between the BladeCenter AMM and the IMM2 - Added power management capability in the IMM2 web interface
Version 2.06, 1AOO42B - Corrected the firmware to prevent users from disabling the IPv6 interface - Fixed a problem that caused the IMM2 to reset itself after running for a period of time - Corrected the SNMP request to disable the IMM2 IPv4 interface so that it disables only IPV4, instead of both IPv4 and IPv6 - Fixed a problem that occasionally caused the server to shut down when the IMM2 is reset - Fixed a problem where the IMM2 incorrectly reported a battery voltage error - Corrected a problem where repeated frequent IMM2 resets causes the IMM2 to run the firmware in its backup partition - Corrected a problem report where the IMM2 did not report a failure to the system profiles script when the chassis UUID is unavailable
Version 2.00, 1AOO40E - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on the x3300 M4 and x3750 M4 -- IMM2 improved error reporting for missing/down CPU in invalid CPU configuration for x4440 M4 - Corrected a problem that caused 3.3V and 5V faults to be reported by IMM2 firmware level 1aoo34z(1.85) on the HS23E blade - Eagle Ray SAS controller LED fault support improvements added for all ITE platforms
Version 1.97, 1AOO36R - Critical Fix: -- Improves the reliability of the CPU and/or memory VRDs. This improvement lowers the occurrence of CPU & memory VRD failures on x3650 M4, x3550 M4 and x3500 M4 - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.95, 1AOO36P (for System x iDataPlex servers) - Added support for NVIDIA K1,K2,K20,K20x GPUs on System x iDataPlex dx360 M4
Version 1.88, 1AOO40A (for PureFlex System Compute Nodes) - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Fixed a problem on Flex Systems where the SNMP get and set authority levels did not work - Fixed a problem on Flex Systems where mounting of remote media in a Linux environment showed a USB error - Fixed a problem on Flex Systems that caused the Remote Control Video Viewer window on a RHEL5.8 client to move when the arrow key is pressed - Fixed a problem on Flex Systems where the SMTP "Test Connection" button did not work when the SMTP port is changed - Corrected the Mezzanine card power fault monitoring on the Flex System x440 Compute Node - Corrected a problem with IBM Fabric Manager configuration from the Flex Chassis Management Module - Added support to retrieve configuration settings from an LDAP server - Added support for the Flex Storage Expansion Node - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state - Changed the default NTP sync interval from 3 minutes to 24 hours - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress
Version 1.85, 1AOO34Z (for BladeCenter blades and System x Servers) - Critical Fix: -- Fixed a potential security vulnerability with node management user accounts (Reference to Security Bulletin CVE-2012-4838) - Fixed a problem where a Blade Open Fabric Manager uncorrectable error can occur when booting the HS23 - Fixed a problem that IMM IPMI command periodically timed out when using HS23 in Chassis with the management network being disabled in some special configurations - Added support for the HS23 to recognize NEBS/Enterprise Mode for Telco chassis (this feature needs Advanced Management Module Firmware BPET62U or later) - Fixed a problem where the ambient temperature is only displayed in degrees Fahrenheit - Fixed a problem where on rack systems that have 2 power supplies installed, the 'Redundancy Power unit has been restored' event is logged every time that the IMM2 is reset - Fixed a problem where a Fan Tach going low (lower critical) event is intermittently asserted when configuring the IMM2 to use an NTP server - Fixed a problem on the web interface where 'local' is not accepted as a top level domain name in the email format when configuring event recipients - Corrected an IMM2 SNMP trap OID to match the prior IMM format - Fixed a problem that prevented an external USB device from being remotely mounted as a floppy drive in Windows Server 2003 - Changed the blue Location led behavior to not blink when a firmware update is in progress - Fixed a problem on the HS23E that causes Preboot DSA to hang in CLI mode when a user accesses it using Serial over LAN - Fixed a problem on rack servers where ASU cannot set IMM.GRP_GroupName.1 and IMM.GRP_GroupName.2 if the string length is 16 characters or longer. The firmware was corrected to allow a maximum length of 64 characters - Added support for CIM indications over https - Added fingerprint checking for SFTP transfers - Added automatic recovery of corrupted UEFI firmware - Added support for authenticated SMTP alerts - Added a display of the users who have a Remote Control session in progress - Provided a request to a Remote Control client to disconnect the session - Added support for the server S3 (sleep) state
Version 1.85, 1AOO34Y (for PureFlex System V7000 Storage Node) - Added support for Flex System V7000 Storage Node
Version 1.79, 1AOO36F - Thermal behavior enhancement on System x iDataPlex dx360 M4
Version 1.78, 1AOO36E - Thermal behavior enhancement for 115W & 95W CPU on System x iDataPlex dx360 M4 - Added support for the Intel KNC 5110p card
Version 1.77, 1AOO32X - Thermal behavior enhancement for 115W CPU on System x iDataPlex dx360 M4
Version 1.75, 1AOO32S - Fixed a problem that a PCI uncorrectable error occurs when using HS23 with CFFh card (44W4479) in the BCS chassis - Fixed a problem where an "Unsupported blade/blower combination" error is reported when using the HS23 in the BCHT chassis configured in Enterprise mode - Fixed a problem in System x3530 M4, where the reported Active Energy Manager input/output power readings are inaccurate - Fixed a problem in System x3530 M4, x3630 M4, where an LDAP account can not login using the AD_CrossDomain tree - Fixed a problem in System x3530 M4, x3630 M4, where a user cannot use the "DNS to Find LDAP server/Extract search domain from login ID" setting from the IMM2 web to access an eDirectory server - Added support for Common Form Factor power supplies Oversubscription in System x3750 M4, Machine Types: 8722, 8733
Version 1.65, 1AOO32O - Support the power supply Over-Subscription feature - Support the 750 Watt DC power supply for System x3650 M4,x3550 M4 - Support IBM 1.2TB High IOPS MLC Mono Adapter, IBM 2.4TB High IOPS MLC Duo Adapter for System x3650 M4, x3550 M4 - Support IBM LLM-SM Dual Port 10GbE SFP+ Adapter for System x3650 M4 - Fixed an abnormal Fan Zone recovery problem - Fixed a problem that IMM2 Email notification doesn't support an e-mail address with the underscore '_' character - Fixed a power policy "Restore" problem - Fixed a problem where the LDAP hostname can't be changed by ASU - Fixed a problem that the length of email address (for SNMP notification) is limited to 32 characters
Version 1.60, 1AOO32P - Fixed a problem where the Chassis Management Module cannot correctly get the Mezzanine card information for the Flex System x220 Compute Node - Fixed a problem where the PreBoot DSA firmware could not be updated under VMWare ESXi 5 through the Flex System Manager's Update Manager - Fixed a problem where an IMM2 communications error can occur if an unexpected response causes VMware to spawn multiple processes when it does not receive the data it expects from the IMM2
Version 1.59, 1AOO32K - Supports System x3300 M4, Machine Types: 7382
Version 1.53, 1AOO30Z - Included an update to the FPGA that fixes an intermittent issue where the CPUs do not show up in a system with a RAID card installed, when the AC is removed and reapplied from the server without allowing sufficient time for the system hardware to completely discharge
Version 1.52, 1AOO34A - Added redundant power supply and hot swap hard drive support in System x3100 M4
Version 1.51, 1AOO30Y - Support for NVIDIA Tesla K10, M2070Q, M2090 GPU cards on System x iDataPlex dx360 M4 - Fixed a problem in System x iDataPlex dx360 M4 where the password expires after creating a new user in the IMM2 web interface - Fixed a problem in System x iDataPlex dx360 M4, when the memory sensor changes from 'critical' to 'warning,' but the severity is not updated in the syslog or the email notification
Version 1.50, 1AOO30W - Supports System HS23, Machine Types: 7875,1929 - Supports System x3650 M4, Machine Types: 7915 - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Added support for the Intel Xeon E5-2643 processor on the HS23 in BCH-R3, BCS and BCHT chassis - Fixed a problem where the IMM2 incorrectly logged an "Unsupported blade/blower combination" on the HS23 in the BC-E 8677 chassis - Fixed a power restore problem on systems that have 2 Delta power supplies installed - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where OpenLDAP Group Authentication filtering function doesn't work - Fixed a problem in System x3650 M4, x3550 M4, x3500 M4, where LDAP account can not login using the AD_CrossDomain tree
Version 1.45, 1AOO28S - Fixed a problem in Flex System x220 where the Chassis Management Module (CMM) Command Line Interface can't display the Mezzanine card information - Fixed a problem in Flex System x220 and x240 where the prebootDSA firmware cannot be updated through Flex System Manager's Update Manager
Version 1.40, 1AOO30T - Supports System x3750 M4, Machine Types: 8722, 8733
Version 1.38, 1AOO30D - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160
Version 1.36, 1AOO30P - Fixed an intermittent remote media failure in system HS23E - Fixed a problem in system HS23E where remote media does not work when two or more users have concurrent remote control sessions
Version 1.34, 1AOO28Q - Supports Flex System Manager Node, Machine Type: 8731 - Supports Flex System x240 Compute Node, Machine Types: 7863, 8737, 8738 - Supports Flex System x220 Compute Node, Machine Types: 2585, 7906
Version 1.32, 1AOO28N - Supports System x3630 M4, Machine Type: 7158 - Supports System x3530 M4, Machine Type: 7160 - Fixed a problem that may see unexpected fan events after power on in x3100 M4 and x3250 M4 systems - Enhanced robustness on I2C bus test
Version 1.30, 1AOO28M - Supports System HS23E, Machine Types: 8038,8039
Version 1.26, 1AOO26N - Supports System x3650 M4, Machine Types: 7915
Version 1.25, 1AOO26K - Supports System x3550 M4, Machine Types: 7914 - Supports System x3500 M4, Machine Types: 7383 - Supports System x iDataPlex dx360 M4, Machine Types: 7912,7913
Version 1.22, 1AOO26O - Supports System HS23, Machine Types: 7875,1929 Problems Fixed: - Fixed a problem where the BOFM configuration may be lost after a blade power cycle - Fixed an LED error indication that occurs on the BPE4 - Fixed a problem where the Info LED lights during the discovery stage - Fixed a problem where an ABR event is not logged - Fixed an intermittent communication problem between the AMM and IMM2 - Fixed a problem that causes the remote media function to hang when a second user attempts to mount remote media - Fixed a problem where the 'break' keyboard function doesn't work with Serial Over LAN
Version 1.21, 1AOO26L - Supports System HS23, Machine Types: 7875,1929
Version 1.10, 1AOO24B - Supports System dx360 M4, Machine Types: 7918,7919
Version 1.05, 1AOO10K - Fixed the false alert issue in redundant PSU model
Version 1.00, 1AOO10I - Initial Release - Supports System x3250 M4, Machine Types: 2583,2587 - Supports System x3100 M4, Machine Types: 2582,2586
(C) Copyright International Business Machines Corporation 2008 - 2014. All rights reserved.
ibm_fw_imm2_1aoo52y-3_78_anyos_noarch_chg
IBM Flex System x222 UEFI Flash Update Version 1.10 (BuildID CCE136R) Change History
Version 1.10 - BuildID: CCE136R ------------------------------------------------- Problem(s) Fixed: - Addressed a problem where more than four Preboot eXecution Environment (PXE) device option ROMs could be loaded even though legacy BIOS code will only support the first 4 devices - Updated high Memory Mapped Input/Output (MMIO) base address to allow use of this memory in VMWare systems - Fixed SMBIOS Type 41 information for SATA Enhancements: - Added support for Intel® Xeon® Processor E5-2600 v2 product family - Added support for Tivoli Key Lifecycle Manager (TKLM) Limitations: Dependencies:
Firmware version: 4.6.281.21 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - OCe10 VFA CNAs stuck in "Switch Independent Mode" - Port Identification fails on Port 1 under uEFI menu for PCIe rack VFA
Incremental Interoperability: - Emulex Dual Port 10GbE SFP+ VFA IIIr for IBM System x - Emulex Dual Port 10GbE SFP+ Embedded VFA IIIr for IBM System x - IBM Flex System CN4054R 10Gb Virtual Fabric Adapter - IBM Ivy Bridge CPU Based Servers
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.281.8 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - HW iSCSI offload is now supported in UFP Mode (UFP limited to IBM Flex) - Server may hang during boot with multichannel disabled with switch default settings. The IBM 10Gb Virtual Fabric Switch has trunking enabled and the Brocade Converged 10Gbe Switch Module has ports in "Access" mode. If the Brocade Converged 10Gbe Switch Module ports are switched to trunking mode, the hang no longer occurs. - When using Config Patterns with virtual MACs the bandwidth settings are are intermittently reset after some number of server reboots.
Incremental Interoperability: - IBM Flex System Fabric SI4093 System Interconnect Module - IBM Flex System EN6131 40Gb Ethernet Switch - IBM Flex System x222 10Gb Virtual Fabric LOM - SLES 11.3 on IBM System x and BladeCenter - Complete NIC/iSCSI/FCoE support for ASU/Config Patterns for Flex and ASU for IBM System x & BladeCenter
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware version: 4.6.166.9 (supported on IBM System x & BladeCenter)
Problems Fixed: - When connected to Cisco Nexus 4k and 5k switches, the virtual link may not recover on a switch port bounce (shut/no shut) in an ESXi environment. A switch port re-bounce will recover the link.
- When connected to Cisco Nexus 4k and 5k switches, OneCommand Manager reports CRC's and there is poor network performance in an ESXi environment
- In some cases of heavy traffic or broadcast storm, users can experience a loss of ethernet connectivity or PSOD (ESXi)
Incremental Interoperability: - ASU/Config Pattern configuration for iSCSI and FCoE (BE3) - UFP for iSCSI (BE3) - Support for using 10Gb ports with legacy 1Gb switches installed in a BladeCenter-S chassis or MSIM/MSIM-T expansion units in a BladeCenter-H or -HT chassis - Update Express System Packs now support Linux errata kernels - ESXi 5.1
Known Issues: - After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- Server may hang during boot with multichannel disabled with switch default settings. The IBM 10Gb Virtual Fabric Switch has trunking enabled and the Brocade Converged 10Gbe Switch Module has ports in "Access" mode. If the Brocade Converged 10Gbe Switch Module ports are switched to trunking mode, the hang no longer occurs.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info available in the Cisco Nexus 4001i Switch Module firmware release notes.
Firmware Version: 4.4.180.3 (Previously supported on IBM Flex)
Problems Fixed:
- 10Gb ports intermittenly linking at 1Gb speed with the IBM Flex System Fabric EN4093/EN4093R 10Gb Scalable Switch. - Switch Configuration after an erase configuration is not reflected after reboot - 'Logical Admin Link' not enabled after applying BOFM in Switch Agnostic mode - IBM pre-boot Diagnostics NIC physical loopback test fails in Command and GUI mode - Multiple cosmetic issues with iSCSI UEFI BIOS - 10Gb ports do not detect 'Link Down' with some switches - When adding an iSCSI hardware target in UEFI through discovery login, the boot target setting is ignored.
Interoperability since previous release:
- UEFI 2.3.1 Compliance - Increased VF count in SR-IOV (was 16 VFs per port, is now 32 VFs per port) - Support for next generation 10GbaseT PHY - Expose IBM Feature On Demand licensing information in UEFI configuration utility - IBM Universal Configuration Manager for Ethernet - IBM Unified Fabric Protocol - Ability to assign Switch Agnostic VLAN IDs without intermediate reboot - Changes to Personality or Multichannel in PXESelect allows further changes to be made w/o reboot - Support for IBM Flex System Fabric CN4093 10Gb Converged Scalable Switch
Known Issues:
- HW iSCSI offload is not currently supported in UFP mode
Firmware Version: 4.1.422.8 (Previously supported on IBM Flex)
Problems Fixed:
- PHY Loopback fails on 10G ports - RH 6.2 and W2k8 servers crashed after shut/no shut the switch port with FCoE connection and 50 vlans configured - DSA: NIC physical loopback test fails in Command and GUI mode - Firmware update fails to update all VPD Code Level fields - DCBX does not converge with FW 4.1.422 on Cicso 5k.
Interoperability Since Previous Release:
- Support for IBM Flex System x440 10Gb Virtual Fabric LOM
Firmware Version: 4.1.422.0 (Previously supported on IBM Flex)
Problems Fixed:
- SR IOV: Unable to ping IPV6 from DUT VF to Peer VF - Reading VPD from BE3 timesout making SR IOV fail in newer kernels - 1Gb devices are being suppressed by kernel during the PCI probe in SLES11 SP2 - MAC Loopback fails when Mgmt Adapter Creation fails - Failure of MAC loopback test after firmware update and warm reboot - Suppress efat dump mailbox commands in the efat dump log - Running ethtool with BE3 takes longer than expected after cable pull - Out of Order CQEs - TRACE_LOG function not printing the messages for some of the VF's - esx4/5 issue. svc target cannot be configured properly - RSCN is not generated by switch when a driver restarts - Port Link stays up even after switch removed
Interoperability Since Previous Release:
- Support for IBM Flex System EN4054 4-port 10Gb Ethernet Adapter - Support for IBM Flex System CN4054 10Gb Virtual Fabric Adapter - Support for IBM Flex System x240 10Gb Virtual Fabric LOM - Support for IBM Flex System Manager 10Gb Virtual Fabric LOM
Firmware Version: 4.2.433.3 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Intermittent link status with IBM Virtual Fabric Switch when set to IBM Virtual Fabric Mode - The option to enable/disable SRIOV on HS23 LOM Port 0 is missing from OneCommand Manager. This selection is available in UEFI F1 setup. - Under high network stress, NMI errors can be seen with x3690 X5 and x3850 X5 - 10GbE ports running at 1GbE speed 10% below wirespeed at certain block sizes. - Unable to perform PXE boot with LPVID assigned to vNIC interface - 1Gb ports of HS23 do not handle tagging properly if multichannel mode enabled (pnic ok). Note: ESX driver patch also required. - Port flapping link after FW upgrade and "reboot" when connected to 10Gb PTM module (DAC)
Interoperability Since Previous Release:
- Support for Emulex Virtual Fabric Adapter Advanced (BE2) for IBM BladeCenter - Support for Emulex Virtual Fabric Adapter (BE2) for IBM BladeCenter - Support for Emulex Virtual Fabric Adapter (BE2) for IBM System X
Known Issues:
- All 10Gb KX4 ports must be used with 10Gb switches. They will not link at 1Gb. This applies to HS23 LOM and IBM BladeCenter VFA adapters only. - IPv6 IP address not visible via IMM GUI for IBM Option 90Y6456
Firmware Version: 4.2.412.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- All VFS on Port 1 on optional Card unreachable from outside the host (x3750 M4) - 'Logical Admin Link' not enabled after applying BOFM in Switch Agnostic mode - IBM pre-boot Diagnostics NIC physical loopback test fails in Command and GUI mode - Multiple cosmetic issues with iSCSI UEFI BIOS - 10Gb ports do not detect 'Link Down' with some switches - 1Gb ports on HS23 LOM not able link up with IBM ICPM (FRU part 44W4486) in BCS chassis - Performance issues with specific DAC cables and SND top of rack switch
Interoperability Since Previous Release:
- UEFI 2.3.1 Compliance - Increased VF count in SR-IOV (was 16 VFs per port, is now 32 VFs per port) - Support for next generation 10GbaseT PHY - Expose IBM Feature On Demand licensing information in UEFI configuration utility
Known Issues:
- All 10Gb ports must be used with 10Gb switches. They will not link at 1Gb. - IPv6 IP address not visible via IMM GUI for IBM Option 90Y6456 - Intermittent link status with IBM Virtual Fabric Switch when set to IBM Virtual Fabric Mode - The option to enable/disable SRIOV on HS23 LOM Port 0 is missing from OneCommand Manager. This selection is available in UEFI F1 setup.
Firmware Version: 4.1.455.6 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Fixed an issue where ASIC randomly hangs losing network connectivity when certain commands are sent from the host. Resulting behavior varies between OS's (Yellow bangs in Windows, PSOD in VMWare) - PHY Loopback fails on 10G ports - UE and hang on LOM or Robalo when powering off Janice in UEFI or PXESelect - Loopback on HS23 now functional in DSAp - DCBX does not converge with firmware on a FCoE fabric - Control C Broken on BE2 - 7 second delay in GET_CARD_ATTRIBUTES command - Emulex VF adapter FCoE link lost on VMware 5.0 - flow control set for 10G Base T phys for autonegotiation - Dynamic link update is not working with NIC UEFI driver - Remove unused definitions in UEFI NIC - Emulex driver expects that the Login Options field be zero - "map r" displays a iSCSI BLK device when no LUNs presented - "X/x Exit without save" does not work as expected - Display proper description as part of EFI Driver Model Related Information - Intermittent "Configuration changed. reset to apply it now?" - Garbled output being displayed at the LUN configuration section. - All Emulex Configuration settings get lost after a reset - Perform additional checks when no Luns are mapped to the target - CHAP name only accepts 6 to 10 characters - Hii ???iSCSI Initiator Configuration??? showing old version screen - iSCSI name is case sensitive - iSCSI HII allows user to select first 8 LUNs as bootable. - iSCSI Boot Enable/Disable option should be port specific - LUN Configuration shows LUN 0, even if no LUNs presented to initiator.
Interoperability Since Previous Release:
- Support for Emulex Virtual Fabric Adapter Advanced (CFFh, 2+2) for IBM BladeCenter
Firmware Version: 4.1.334.47 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- NCSI transmit workaround for IBM - Issues with data reporting when BOFM enabled - Improved network performance throughput - Issues with IBM Management network performance - Logical link status for IBM mezz card shown as 'N/A' - Serial Over LAN fails when more than one blade installed with a single switch - Removed UEFI menu items for unsupported functions on a port - Issues with diagnositics in virtual NIC/UMC mode - Issues with MAC and PHY loopback on OneConnect devices - Several issues with FCoE on some OEM fabric switches
Interoperability Since Previous Release:
- Support for HS23 Virtual Fabric LAN on Motherboard - Support for VFA III (95Y3762, 95Y3768), 90Y6456 - Support for IBM's Features on Demand (FOD) - Formal support for SR-IOV
Firmware Version: 4.0.1062.0 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- iLab Tucson - lpfc Device Resets and path failures continue after error inject. - Writes do not complete when running LIP test on BE3 port 2 - IPV6 implementations no longer experience an unrecognized routing type error. - VLAN tagging is now disabled on the OneConnect UCNA when multichannel is disabled. - UEFI/BIOS-assigned LPVIDs now function properly on the OneConnect 10102-based UCNA. - OneConnect UCNAs no longer send and receive only double-tagged packets and discard all other packets. - PHY, MAC, and External loopback tests no longer fail on all platforms. - Firmware now returns the proper OneConnect UCNA model number. - IPV6 implementations no longer experience an unrecognized routing type error. - Installing Windows 2008 or Windows 2008 R2 on remote iSCSI disks no longer causes the system to hang. - Issues no longer occur when resetting a server configured for multipathing on VMware ESX systems. - VLAN tagging is now disabled on the OneConnect UCNA when multichannel is disabled. - UEFI/BIOS-assigned LPVIDs now function properly on the OneConnect 10102-based UCNA. - OneConnect UCNAs no longer send and receive only double-tagged packets and discard all other packets. - An adapter hardware error no longer occurs when running I/O with LUNs on x86 platforms. - Changing from Convergence Enhanced Ethernet (CEE) to Chassis Internal Network (CIN) and then rebooting no longer fails to link-flap (CIN Fabric Login (FLOGI) now occurs). - PHY, MAC, and External loopback tests no longer fail on all platforms. - Firmware now returns the proper OneConnect UCNA model number. - DCB settings can now be configured. - (iSCSISelect) When enabling DHCP for an iSCSI initiator, the Emulex iSCSI Network Configuration utility now waits approximately 20 seconds to make a DHCP connection before returning control. - (FCoE BootBIOS) FCF CEE parameters for Boot from SAN configuration are now saved properly.
Interoperability Since Previous Release:
- Added support for switch-independent multichannel mode. - Added support for IBM Virtual Fabric 10Gb RackSwitch firmware 6.8.1.0. - Added support for IBM Virtual Fabric 10G Switch Module firmware 6.8.1.0. - Added support for Fibre Channel over Ethernet (FCoE) on rack systems. - Added support for iSCSI hardware offload on rack systems. - Added support for Cisco Nexus 5000-series switches.
=============================================== Change History =============================================== Document Name: Change History Document Status: IBM General Avalibility Document Version: 3.2.3 Latest Driver Version: 3.2.3.0 Document Updated: 05/30/2013 Product: Brocade FC/NIC/CNA
=================================================
Please visit www.brocade.com/hba for full documentation, additional drivers, and management applications.
Version 3.2.3.0 New Features and Feature Enhancement: - Support for patching firmware via boot image - Support for Linux PTP - Support for UEFI Health Check Protocol - Support for SLES11SP3
Version 3.2.1.0 New Features and Feature Enhancement: - Support for "IBM Flex System FC5024D 4-port 16Gb FC Adapter" PART_NUMBER "95Y2381" - Support for RHEL5.9 and RHEL6.4
Fixes and Enhancements: - Enhanced Linux driver data path to properly handle IPv6 packets. - Enhanced Linux driver to make sure user configured path tov value is persistent and is not changed due to change in dev_loss_tmo.
Version 3.2.0.0 Release for FC/NIC/CNA
New Features and Feature Enhancement: - Updated code for Brocade 1867 IBM Flex System FC5022 FC Adapter for x22 - BB Credit Recovery - Forward Error Correction (FEC) - Diagnostic Port (D-Port) - LUN Level IO Latency/Stats - UCM (Unified Configuration Manager) - Windows Network Performance and scalability enhancement
Fixes or enhancements: - For Brocade 8x5/4x5, I/O interrupt latency values are dynamically updated. Changes are effective for all the ports on the given adapter. - Addressed infrequent PSOD in VMware ESX with iSCSI or VLAN configured traffic in DCB enabled network. - Enhanced BR1860 Tape IO performance. - Improved BR1860 initialization on Xen kernel.
Version 3.1.0.1 Release for 16G FC/NIC/CNA
Adapter Features - Updated code for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A
Version 3.0.3.1 Initial release for 16G FC/NIC/CNA
Adapter Features - Initial support for Brocade 1867 IBM 16G Mezzanine Fabric Adapter.
HBA - Fibre Channel 16G Support
Fixes and Enhancements: N/A brcd_fw_cna_3_2_3_0_linux_32-64_chg
=============================================================================== Emulex FC/FCoE Device Driver for Linux ===============================================================================
Driver Version: 8.2.2.26 (supported on IBM System x, BladeCenter and Flex)
Problems Fixed: - RHEL 5.8 x86 blade crashes during FCoE failover test - Execution of internal loopback causes a crash - Issue which can cause multipath failover to not work properly
Incremental Interoperability: - IBM Flex System FC5052 2-port 16Gb FC Adapter - IBM Flex System FC5054 4-port 16Gb FC Adapter - IBM Tape unit interoperability - see SSIC for more information
Device Driver Version: 8.2.2.15 (Supported for IBM Rack & BladeCenter)
Problems Fixed: - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - OXID Reused before RA_TOV without RRQ to recover - Intermittently storage paths will not recover after switch reboot
Driver Version: 8.2.1.4 (Previously supported on IBM Flex)
Problems Fixed: - Fixed debug helper routine failed to dump CQ and EQ entries in non-MSI-X mode - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service - Fixed boot from san failure when SLI4 FC device presented on the same PCI bus - Fix ABTS recovery to be FC spec compliant - Fixed not reporting logical link speed to SCSI midlayer when QoS not enabled - Fix performance problem in pt2pt mode - Fixed SCSI host create showing wrong link speed on SLI3 HBA ports - Update text for misconfigured port messages - Fix discovery bug when swapping cables
Interoperability since previous release: - No new interoperability
Driver Version 8.2.0.145 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed: - Kernel panics with FCoE on HS23 in SLES 11.2 x86_64. Also requires a SLES11.2 kernel update - FLOGI sent with Class 2 in-order bit set when Class 2 is set as unsupported class of service
Interoperability since previous release: - RHEL6.3 GA Kernel
Driver Version 8.2.0.134 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed: - Fixed system crash due to not providing SCSI error-handling host reset handler - Debug helper utility routines for dumping various SLI4 queues - Fix unsol abts xri lookup - Fixed issues with LPe16000 to LPe16000 discovery - Fix driver crash during back-to-back ramp events - Reregister VPI for SLI3 after cable moved to new Saturn port - Fix log message 2597 displayed when no error is detected - Fixed FCP LOG for easier Finisar trace correlation - Fix kernel panic when going into to sleep state - Fix error message displayed even when not an error - Fix Read Link status data - Fix unable to create vports on FCoE SLI4 adapter - Fix initiator sending flogi after acking flogi from target - Fix the case where an array controller does not apply FCP priority rules - Added support for handling SLI4-port XRI resource-provisioning profile change - Change default DA_ID support from disabled to enabled - Fix bug with driver unload leaving a scsi host for a vport around - Update copyright date for files modified in 2012 - Fix bug with mailbox handling of REG_VFI and cable pull - Used PCI configure space read to flush PCI function reset register write - Update copyright date for files modified in 2012 - Fixed system panic when extents enabled with large number of small blocks - Fixed system panic during EEH recovery - Fix resource leak when acc fails for received plogi - Fix SLI4 driver module load and unload test in a loop crashes the system - Fix missing CVL event causing round-robin FCF failover process to stop - Fix deadlock during adapter offline request - Fix same RPI registered multiple times after HBA reset - Fix driver handling of XRI Aborted CQE response - Fix port and system failure in handling SLI4 FC port function reset - Fix bug with driver not sending a LOGO with vport delete - Fix KERNEL allocation while lock held - Make BA_ACC work on a fully qualified exchange - Fix for SLI4 Port delivery for BLS ABORT ACC - Fix ndlp nodelist not empty wait timeout during driver unloading - Fix mailbox and vpi memory leaks - Fix for FDISC failures after firmware reset or link bounce - Limit what management ELS and CT commands can be issued according to latest management specification - Fix for driver using duplicate RPIs after 16Gb/s adapter port reset - Fix discovery problem when in pt2pt - Fixed failure in handling large CQ/EQ identifiers in an IOV environment - Fix Locking code raises IRQ twice - Fix driver not returning when bad ndlp found in abts error event handling - Added driver logs in area of SLI4 port error attention and reset recovery
Driver Version 8.2.0.122 (Previously supported on IBM SystemX & BladeCenter)
Problems Fixed:
- Fix bug with driver returning the wrong ndlp - Fix driver behavior when receiving an ADISC - Fixed PCI loopback diagnostic test through hbaCmd on SLI4 port failure - Fixed unbounded firmware revision string from port caused the system panic - Fix driver does not reset port when reset is needed during - Changed SLI4 FC port internal loopback from outer serDes to inner internal - Fix ELS FDISC failing with local reject / invalid RPI - Fix REG_RPI fails on SLI4 HBA putting NPort into NPR state - Fix NMI seen due to CQE starvation - Fixed SLI4 FC port obtain link type and number dependent on link connection - Fixed SLI4 FC port internal loopback without SFP and external link/loopback plug - Fix driver incorrectly building fcpCdb during scsi command prep - Fixed FCP EQ memory check prevent initialize to single interrupt vector case - Fixed system panic duringEEH recovery on SLI4 FC port - Fix FLOGI fails with invalid RPI (0x04) after connecting to a arbitrated loop - Fix ELS SCR failing with local reject / invalid RPI - Fix SLI4 port failures after firmware reset or dump - Fix port reset log messages indicate error when no error is seen - Fixed an issue where HBQ buffers are uninitialized in the base driver - Fixed missing hbalock protection on setting/clearing bit in phba->link_flag - Fixed logging mailbox error log messages during SLI4 FW download using HbaCmd - Fixed illegal state transition during driver unload - Fixed SLI4 FC port Internal and External loopback diagnostic tests - Fix bug with driver erroneously logging a kernel error message - Fix a crash while deleting 256 vports - Fix vport never finished discovery if switch runs out of resources - Fix kernel build warnings - Fix kernel panic when putting board in offline state twice - Fix PCI read failure looks like a over temperature event - Fixed driver event reporting to mgmt on error attention due to forced dump - Fix not displaying firmware rev for BE UCNA boards - Fixed ABTS failure logic not rediscovering targets - Fix bug with driver not byte swapping extended mailbox data - Fix premature ndlp cleanup after second target LOGO - Fix Link pull causes I/O failures - Add loop support for sli4 fc - Fixed OCM failing COMN_READ_OBJECT and COMN_WRITE_OBJECT mailbox pass-through - No longer read fcoe parameters if board is not fcoe - Added restore state and error log when sysfs board_mode attribute access failed - Added support for SLI4_CONFIG non-embedded COMN_GET_CNTL_ADDL_ATTR pass-through - Added support for SLI4 FC port persistent linkdown through config region 23 - Fix for ABTS.Do not free original IOCB whenever ABTS fails - Fixed Linux driver inconsistency in reporting FC host port-state through OCM - Fix firmware upgrade attempt on unsupported adapter - Fix incomplete message number 2889 - Fix system crash when Lancer fails to initialize - Fixed fcpi param length when not using an sgl - Fix virtual fabrics bit set in FLOGI incorrectly - Fix unsupported link speed accepted by SLI4 port - Incremented minor management version to reflect additional "protocol" sysfs attribute - Fix kernel build warnings - Modify WQ handling to use entry_repost - Added a sysfs attribute "protocol" to report SLI4 port link protocol type - Added SLI4 INTF_TYPE and SLI_FAMILY as sub-field to the fwrev sysfs attribute - Added structure to support T10 DIF in SLI4 - Fix performance slowed due to too many register accesses - Fix a possible driver crash when cfg_fcp_eq_count is zero - Fixed non-embedded COMMON_GET_CNTL_ATTR mbox command failed with status 0x4 - Changed the way of SLI4 device detecting physical port name - Fixed FCP policy exchange management rule parsing - Add new check to lpfc_decode_firmware_rev to handle releases that have an 'X' - Fixed RPI leaks in ELS protocol handling - Fix kernel crash during boot with SLI4 card installed - Fixed NPIV FDISC failure on SLI4 if-type 2 ports - Moved fcp policy structs - Fixed driver failed to follow IP reset procedure in SLI4 error attention handler - Fixed fcp underrun reporting - Fix sysfs lists fabric name for port that has been disconnected from fabric - Added support for policy exchange management - Changed the timeout to 300 seconds for SLI_CONFIG (0x9B) mailbox command - Fixed a driver handling IP reset issue when PCI read return error - Fixed casting problem in calculating tx_words statistics - Fixed compiler warningdue to uninitialized local variable - Added proper error code return for libdfc calling API to make proper decisions - Fix sli4 mailbox status code. Management software has dependencies - Made proper error code return for libdfc calling API to make proper decisions - Made error log include PCI BAR bitmap from kernel when enable PCI device failed - Fixed incomplete scsi messages displayed - Change log message in lpfc_sli_set_dma_length() - Completed missed FCF priority failover - Fixed not recovering SLI port in handling error attention with RN bit set - Fixed two crash cases when unsolicted ELS ECHO_CMD is received - Fix direct connect does not come up for SLI4 FC ports - Fixed long wait when firmware reset to a SLI port without required privilege - Fix driver firmware update to match new firmware image format - Fix SLI4 CT handling for sequences > 4K - Fixed handling of unsolicited frames for vports - Fixed crash when aborting els IOs - Fixed handling of CVL for vports - Fix up CT and oxid/rxid for unsol rcv frames - Fixed mailbox double free panic - Added fcf priority record selection for fcf failover - Fixed compiler warning for putting large amount of memory on stack - Fixed hbacmd listhbas took very long time when remote initiators present in zone - Fixed driver build not building in debugfs even if kernel CONFIG_DEBUG_FS=y is set - iDiag added SLI4 device PCI BAR memory mapped reigster access methods - iDiag changed command structure data array indexing by using macro defines - Ported iDiag pass-through multi-buffer mbox command capture and dump extension - Ported new SLI4 FC device loopback test and link diagnostic test supports - FLOGI payload has Multiple N_port_ID set when lpfc_enable_npiv clear - Add sysfs logging when writeable parameters are changed - Fixed new ASIC device-mgmt SYSFS pass-through failed multi-buffer fw download - Fixed memory leak due to failure to release mailbox command when completed - Brought debugfs accessing new ASIC extents information into the iDiag framework - Added wait for SLI port status register for readyness following firmware reset - Consolidated duplicating macro definitions - Implement debugfs support for resource extents - iDiag method for read write bitset bitclear access to new ASIC control registers - Fixed failure in pass-through mbox command with multiple number of large buffers - iDiag method for endian explicit dumping at iussue SLI4 mailbox command routine - iDiag ported debugfs method for dumping mbox from SLI4 issue mbox cmd routine - Added request for PCI funndamental reset to support EEH recover on P7 platform - iDiag ported debugfs inline mailbox command capture and dump utility - Fixed failure to enable PCIe AER prevent driver initialize and attach to device - Fix EEH recovery so state is saved after every PCI reset for SLI4 - Moved INIT_LIST_HEAD to inside of lpfc_mgmt_issue_sli_cfg_ext_mbox routine - New ASIC device management pass-through mbox extension with multi-buffer support - Fix FC Port swap on SLI3 adapters - Fixed Virtual link loss during Face plate failover test - Fix vpi initialization in lpfc_init_vfi - Added driver capability of reseting new ASIC firmware and device from sysfs entry - Added capability of inducing new ASIC firmware dump obj file to flash filesystem - Add firmware upgrade code to driver - Added 100ms delay before driver action following IF_TYPE_2 function reset - Fragment ELS and SCSI SGE lists based on Extent regions - Fixed potential missed SLI4 device initialization failure conditions - FixedBack to back Flogis sent without a logo - Add model names for new hardware - Fix bug with lpfc driver not updating the wwnn and wwpn after a name change - Set the maximum SGE size to 0x80000000 when HBA does not have any restriction - Fix SLI3 and non-NPIV crashes with new extent code - Fix CT command never completing on Big Endian system - Refactor lpfc_sli4_alloc_extent some more - Restore SLI4_PARAMETER mailbox can fail as nonerror functionality - Do not post RPI Headers to SLI4 port that support extents - Framework for new ASIC device management multi-buffer mbox passthrough support elx_dd_fc_ibm1212-8_2_2_26-1_rhel5_32-64_chg